Microscopy Morphology — A novel pencil graphite electrode modified with an iron-based conductive metal-organic framework exhibited good ability in simultaneous sensing bisphenol A and bisphenol S

Measurement evidence

Microscopy Morphology

A novel pencil graphite electrode modified with an iron-based conductive metal-organic framework exhibited good ability in simultaneous sensing bisphenol A and bisphenol S · Chen J.-Y., Weng Y.-X., Han Y.-H. et al. · Ecotoxicology and Environmental Safety · 2024 · 116065

1 measurement group · 3 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

FESEM, TEM, HRTEM, dark-field TEM elemental mapping, EDS

Fe-HHTP powder · Powder

FESEM spot 3.0, magnification 50000x, high voltage 10.0 keV; TEM/HRTEM used for microstructure and elemental mapping.

Context
pristine Fe-HHTP powder characterised before electrode application
Measurement source
2,4,5 · 2.2.1; 3.1 · Fig. 1A-E
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
EDS/TEM-mapping elementsC, O, and Fe present and uniformly distributedText
Qualitative
5 · 3.1 · Fig. 1B,E
HRTEM lamellar structureclear and ordered lamellar structureText
Qualitative
5 · 3.1 · Fig. 1D
Fe-HHTP morphologyrod-shaped crystal nanomaterial with uniform structure and flocculent surfaceText
Qualitative
5 · 3.1 · Fig. 1A