Electrical Transport — A Water-Stable Proton-Conductive Barium(II)-Organic Framework for Ammonia Sensing at High Humidity

Measurement evidence

Electrical Transport

A Water-Stable Proton-Conductive Barium(II)-Organic Framework for Ammonia Sensing at High Humidity · Guo K., Zhao L., Yu S. et al. · Inorganic Chemistry · 2018 · 7104-7112

5 measurement groups · 71 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Time-dependent proton conductivity monitoring

Pressed pellet of MOF 1 · Pellet

Continuous conductivity testing for 8 h at 100 deg C and 98% RH.

Temperature
373.15
Atmosphere
98% RH
Geometry
pressed pellet
Context
pristine MOF 1 pellet
Measurement source
p005 · Proton Conduction of MOF 1 · Figure S14
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
time-dependent conductivity stabilityproton conductivity remained basically unchanged after 8 h at 100 deg C and 98% RHText
Approximate
p005 · Proton Conduction of MOF 1 · Figure S14

Equivalent-circuit fitting of Nyquist plots with ZSimpWin

Pressed pellet of MOF 1 · Pellet

Nyquist plots at 30 and 100 deg C under 98% RH fitted with LR(C(R(Q(R(C(RW)))))).

Temperature
303.15 and 373.15
Atmosphere
98% RH
Geometry
pressed pellet
Context
pristine MOF 1 pellet
Measurement source
p005 · Figures S1-S2 · Figure S1; Figure S2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
equivalent circuit used for 30/100 deg C 98% RH fittingLR(C(R(Q(R(C(RW))))))Caption
Exact Reported
p005 · Figures S1-S2 · Figure S1

Arrhenius analysis of impedance spectra under NH3

MOF 1 pellet during humid NH3 exposure · Pellet

25 ppm NH3, 30-100 deg C, at 75% or 98% RH; activation energy from Arrhenius plots.

Temperature
303.15-373.15
Atmosphere
humidified NH3
Geometry
pressed pellet sensor
Context
guest-loaded MOF 1 pellet
Measurement source
p007 · Impedance Ammonia Sensing · Figure 10; Figures S19-S20
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
dry ammonia/water-absence controlno proton conduction and ammonia recognition in the absence of water or under dry ammonia at 30 deg CText
Qualitative
p007 · Impedance Ammonia Sensing
activation energy under 25 ppm NH3 at 75% RH0.73 eVText
Exact Reported
p007 · Impedance Ammonia Sensing · Figure 10
activation energy under 25 ppm NH3 at 98% RH0.14 eVText
Exact Reported
p007 · Impedance Ammonia Sensing · Figure 10

Conductivity calculated from NH3-exposure impedance spectra

MOF 1 pellet during humid NH3 exposure · Pellet

30 deg C, 75/85/93/98% RH, 1-25 ppm NH3; conductivities calculated from impedances.

Temperature
303.15
Atmosphere
humidified synthetic air plus NH3
Geometry
pressed pellet sensor
Context
guest-loaded MOF 1 pellet during NH3 exposure
Measurement source
p008 · Impedance Ammonia Sensing · Table 4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
proton conductivity under 10 ppm NH3 at 75% RH and 30 deg C6.13e-07 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 15 ppm NH3 at 75% RH and 30 deg C6.25e-07 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 20 ppm NH3 at 75% RH and 30 deg C6.86e-07 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 25 ppm NH3 at 75% RH and 30 deg C7.18e-07 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 5 ppm NH3 at 75% RH and 30 deg C5.52e-07 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 10 ppm NH3 at 85% RH and 30 deg C3.39e-06 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 15 ppm NH3 at 85% RH and 30 deg C4.08e-06 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 20 ppm NH3 at 85% RH and 30 deg C4.98e-06 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 25 ppm NH3 at 85% RH and 30 deg C5.36e-06 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 3 ppm NH3 at 85% RH and 30 deg C2.35e-06 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 5 ppm NH3 at 85% RH and 30 deg C2.51e-06 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 10 ppm NH3 at 93% RH and 30 deg C4.47e-06 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 15 ppm NH3 at 93% RH and 30 deg C5.4e-06 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 1 ppm NH3 at 93% RH and 30 deg C2.75e-06 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 20 ppm NH3 at 93% RH and 30 deg C6.36e-06 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 25 ppm NH3 at 93% RH and 30 deg C7.89e-06 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 3 ppm NH3 at 93% RH and 30 deg C3.16e-06 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 5 ppm NH3 at 93% RH and 30 deg C3.52e-06 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 10 ppm NH3 at 98% RH and 30 deg C2.58e-05 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 15 ppm NH3 at 98% RH and 30 deg C3.06e-05 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 1 ppm NH3 at 98% RH and 30 deg C1.37e-05 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 20 ppm NH3 at 98% RH and 30 deg C3.55e-05 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 25 ppm NH3 at 98% RH and 30 deg CMarked as a best value within this paper3.88e-05 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 3 ppm NH3 at 98% RH and 30 deg C1.66e-05 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4
proton conductivity under 5 ppm NH3 at 98% RH and 30 deg C1.96e-05 S cm-1Table
Exact Reported
p008 · Table 4 · Table 4

Quasi-four-probe electrochemical impedance spectroscopy; PARSTAT 2273; 0.1 Hz-1 MHz; 100 mV AC

Pressed pellet of MOF 1 · Pellet

Pressed pellet equilibrated at least 18 h under controlled RH; conductivity from Nyquist semicircle fitting using sigma = T/(RS).

Temperature
303.15-373.15
Atmosphere
controlled H2O relative humidity
Geometry
pressed pellet; thickness and cross-sectional area not reported
Context
pristine MOF 1 pellet under humid water vapour
Measurement source
p002-p005 · Proton Conduction Measurement; Proton Conduction of MOF 1 · Table 2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
proton conductivity in humid air/water vapour at 68% RH and 100 deg C2.05e-06 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 68% RH and 50 deg C6.71e-08 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 68% RH and 60 deg C1.91e-07 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 68% RH and 70 deg C4.83e-07 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 68% RH and 80 deg C8.83e-07 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 68% RH and 90 deg C9.34e-07 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 75% RH and 100 deg C5.69e-06 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 75% RH and 30 deg C5.52e-07 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 75% RH and 40 deg C6.01e-07 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 75% RH and 50 deg C9.21e-07 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 75% RH and 60 deg C1.01e-06 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 75% RH and 70 deg C1.4e-06 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 75% RH and 80 deg C1.96e-06 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 75% RH and 90 deg C3.98e-06 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 85% RH and 100 deg C5.09e-05 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 85% RH and 30 deg C2.21e-06 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 85% RH and 40 deg C3.3e-06 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 85% RH and 50 deg C5.66e-06 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 85% RH and 60 deg C1.13e-05 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 85% RH and 70 deg C1.43e-05 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 85% RH and 80 deg C1.73e-05 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 85% RH and 90 deg C2.7e-05 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 93% RH and 100 deg C0.000668 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 93% RH and 30 deg C2.69e-06 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 93% RH and 40 deg C1.32e-05 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 93% RH and 50 deg C2.13e-05 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 93% RH and 60 deg C2.95e-05 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 93% RH and 70 deg C3.4e-05 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 93% RH and 80 deg C4.54e-05 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 93% RH and 90 deg C0.000325 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 98% RH and 100 deg CMarked as a best value within this paper0.00136 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 98% RH and 30 deg C1.17e-05 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 98% RH and 40 deg C1.82e-05 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 98% RH and 50 deg C2.6e-05 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 98% RH and 60 deg C5.09e-05 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 98% RH and 70 deg C0.000109 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 98% RH and 80 deg C0.000256 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
proton conductivity in humid air/water vapour at 98% RH and 90 deg C0.000409 S cm-1Table
Exact Reported
p004 · Table 2 · Table 2
unusable low-RH impedance conditionno useful impedance value at 30 and 40 deg C under 68% RH or belowText
Qualitative
p005 · Proton Conduction of MOF 1
activation energy under 68% RH0.71 eVText
Exact Reported
p005 · Proton Conduction of MOF 1 · Figure 6
activation energy under 98% RH0.67 eVText
Exact Reported
p005 · Proton Conduction of MOF 1 · Figure 6