Sensing Application — A Water-Stable Proton-Conductive Barium(II)-Organic Framework for Ammonia Sensing at High Humidity

Measurement evidence

Sensing Application

A Water-Stable Proton-Conductive Barium(II)-Organic Framework for Ammonia Sensing at High Humidity · Guo K., Zhao L., Yu S. et al. · Inorganic Chemistry · 2018 · 7104-7112

3 measurement groups · 60 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Gas-response and selectivity analysis from impedance response

MOF 1 pellet during humid NH3 exposure · Pellet

NH3 concentration-response at 30 deg C and 75-98% RH; selectivity measured against ten interfering gases at 25 ppm, 30 deg C, 98% RH.

Temperature
303.15
Atmosphere
humidified synthetic air plus target gas
Geometry
pressed pellet Pt-mesh sensor
Context
guest-exposed pristine MOF 1 pellet
Measurement source
p006-p007 · Impedance Ammonia Sensing · Figures 8-9; Table S3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
response bound for non-NH3 gasesresponses lower than 19% toward most tested gasesText
Approximate
p007 · Impedance Ammonia Sensing · Figure 9
NH3 detection limit at 75% RH5 ppmSI Table
Exact Reported
p003 · Table S3 · Table S3
NH3 detection limit at 85% RH3 ppmSI Table
Exact Reported
p003 · Table S3 · Table S3
NH3 detection limit at 93% RH1 ppmSI Table
Exact Reported
p003 · Table S3 · Table S3
NH3 detection limit at 98% RHMarked as a best value within this paper1 ppmSI Table
Exact Reported
p003 · Table S3 · Table S3
lowest discerned NH3 response at 75% RH11.21% toward 5 ppm NH3Text
Exact Reported
p006 · Impedance Ammonia Sensing · Figure 8
lowest discerned NH3 response at 85% RH6.41% toward 3 ppm NH3Text
Exact Reported
p006 · Impedance Ammonia Sensing · Figure 8
lowest discerned NH3 response at 93% RH2.32% toward 1 ppm NH3Text
Exact Reported
p006 · Impedance Ammonia Sensing · Figure 8
lowest discerned NH3 response at 98% RH21.14% toward 1 ppm NH3Text
Exact Reported
p006 · Impedance Ammonia Sensing · Figure 8
gas response to 25 ppm NH3 at 75% RH30.09%Text
Rounded Reported
p006 · Impedance Ammonia Sensing · Figure 8
gas response to 25 ppm NH3 at 85% RH143%Text
Exact Reported
p006 · Impedance Ammonia Sensing · Figure 8
gas response to 25 ppm NH3 at 93% RH193%Text
Exact Reported
p006 · Impedance Ammonia Sensing · Figure 8
gas response to 25 ppm NH3 at 98% RHMarked as a best value within this paper243%Text
Exact Reported
p006 · Impedance Ammonia Sensing · Figure 8
NH3 selectivity ratio versus acetoneS = 83.5Text
Exact Reported
p007 · Impedance Ammonia Sensing · Figure 9
NH3 selectivity ratio versus benzeneS = 96.8Text
Exact Reported
p007 · Impedance Ammonia Sensing · Figure 9
NH3 selectivity ratio versus COS = 96.8Text
Exact Reported
p007 · Impedance Ammonia Sensing · Figure 9
NH3 selectivity ratio versus CO2S = 19.74Text
Exact Reported
p007 · Impedance Ammonia Sensing · Figure 9
NH3 selectivity ratio versus EtOHS = 14.24Text
Exact Reported
p007 · Impedance Ammonia Sensing · Figure 9
NH3 selectivity ratio versus H2S = 96.0Text
Exact Reported
p007 · Impedance Ammonia Sensing · Figure 9
NH3 selectivity ratio versus H2SS = 13.32Text
Exact Reported
p007 · Impedance Ammonia Sensing · Figure 9
NH3 selectivity ratio versus MeOHS = 12.74Text
Exact Reported
p007 · Impedance Ammonia Sensing · Figure 9
NH3 selectivity ratio versus N2S = 98.8Text
Exact Reported
p007 · Impedance Ammonia Sensing · Figure 9
NH3 selectivity ratio versus O2S = 100.8Text
Exact Reported
p007 · Impedance Ammonia Sensing · Figure 9
SI comparative table gas response at 75% RH30% (to 25 ppm)SI Table
Exact Reported
p003 · Table S3 · Table S3
SI comparative table gas response at 85% RH143% (to 25 ppm)SI Table
Exact Reported
p003 · Table S3 · Table S3
SI comparative table gas response at 93% RH193% (to 25 ppm)SI Table
Exact Reported
p003 · Table S3 · Table S3
SI comparative table gas response at 98% RH243% (to 25 ppm)SI Table
Exact Reported
p003 · Table S3 · Table S3

Electrochemical impedance ammonia sensing; PARSTAT 2273 in homemade chamber with Pt mesh electrodes

MOF 1 pellet during humid NH3 exposure · Pellet

30 deg C, 75/85/93/98% RH, NH3 concentrations 0-25 ppm in dry synthetic air/water vapour stream.

Temperature
303.15
Atmosphere
humidified synthetic air plus NH3
Geometry
pressed pellet in Pt mesh anode/cathode testing chamber
Context
guest-loaded MOF 1 pellet during NH3 exposure
Measurement source
p002-p006 · Gas Sensor Characterizations; Impedance Ammonia Sensing · Figure 1; Table 3; Figure 7
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
impedance under 10 ppm NH3 at 75% RH and 30 deg C7.44e+05 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 15 ppm NH3 at 75% RH and 30 deg C6.9e+05 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 20 ppm NH3 at 75% RH and 30 deg C6.78e+05 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 25 ppm NH3 at 75% RH and 30 deg C6.48e+05 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 5 ppm NH3 at 75% RH and 30 deg C7.58e+05 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 10 ppm NH3 at 85% RH and 30 deg C1.37e+05 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 15 ppm NH3 at 85% RH and 30 deg C1.14e+05 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 20 ppm NH3 at 85% RH and 30 deg C9.34e+04 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 25 ppm NH3 at 85% RH and 30 deg C8.67e+04 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 3 ppm NH3 at 85% RH and 30 deg C1.98e+05 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 5 ppm NH3 at 85% RH and 30 deg C1.85e+05 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 10 ppm NH3 at 93% RH and 30 deg C1.1e+05 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 15 ppm NH3 at 93% RH and 30 deg C8.61e+04 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 1 ppm NH3 at 93% RH and 30 deg C1.69e+05 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 20 ppm NH3 at 93% RH and 30 deg C7.31e+04 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 25 ppm NH3 at 93% RH and 30 deg C5.89e+04 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 3 ppm NH3 at 93% RH and 30 deg C1.47e+05 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 5 ppm NH3 at 93% RH and 30 deg C1.32e+05 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 10 ppm NH3 at 98% RH and 30 deg C1.79e+04 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 15 ppm NH3 at 98% RH and 30 deg C1.52e+04 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 1 ppm NH3 at 98% RH and 30 deg C3.4e+04 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 20 ppm NH3 at 98% RH and 30 deg C1.31e+04 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 25 ppm NH3 at 98% RH and 30 deg C1.2e+04 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 3 ppm NH3 at 98% RH and 30 deg C2.81e+04 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3
impedance under 5 ppm NH3 at 98% RH and 30 deg C2.37e+04 ohmTable
Exact Reported
p005-p006 · Table 3 · Table 3

Dynamic response/recovery cycling from impedance versus time

MOF 1 pellet during humid NH3 exposure · Pellet

25 ppm NH3 at 30 deg C and 75-98% RH for response time; repeated cycling at 30 deg C and 98% RH.

Temperature
303.15
Atmosphere
humidified NH3 and recovery under humid water vapour/air
Geometry
pressed pellet sensor
Context
guest-loaded/recovered MOF 1 pellet
Measurement source
p012 · Figures S16-S17 · Figure S16; Figure S17
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
ammonia removal in air0.5 h in airText
Exact Reported
p006 · Impedance Ammonia Sensing
ammonia removal under vacuum5 min in vacuumText
Exact Reported
p006 · Impedance Ammonia Sensing
recovery time after NH3 blown outwithin 10 minText
Approximate
p006 · Impedance Ammonia Sensing · Figure S17
response time to 25 ppm NH3 at 75% RHnearly 13 minText
Approximate
p005 · Impedance Ammonia Sensing · Figure S16
response time to 25 ppm NH3 at 85% RHnearly 12 minText
Approximate
p005 · Impedance Ammonia Sensing · Figure S16
response time to 25 ppm NH3 at 93% RHnearly 10 minText
Approximate
p005 · Impedance Ammonia Sensing · Figure S16
response time to 25 ppm NH3 at 98% RHnearly 8 minText
Approximate
p005 · Impedance Ammonia Sensing · Figure S16
reversible response cyclesmore than 10 successive cyclesText
Range
p006 · Impedance Ammonia Sensing · Figure S17