Electrochemistry Application — A Conductive Metal−Organic Framework Based on Triptycene Ligand: An Effective Electrochemical Sensor for Glucose and H2O2 Detection in Food and Human Serum

Measurement evidence

Electrochemistry Application

A Conductive Metal−Organic Framework Based on Triptycene Ligand: An Effective Electrochemical Sensor for Glucose and H2O2 Detection in Food and Human Serum · Hu Q., Wu J., Ling C. et al. · Journal of the Electrochemical Society · 2023 · 037512

1 measurement group · 1 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Three-electrode electrochemistry

Cu-HHTT/CF working electrode · Electrode

CHI 760E workstation; platinum wire counter electrode; Cu-HHTT/CF working electrode; Hg/HgO reference for glucose and Ag/AgCl reference for H2O2.

Temperature
room temperature
Geometry
working electrode geometric area 0.2 x 0.2 cm^-2
Context
target electrode and bare-CF controls
Measurement source
3 · Electrochemical measurements
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Working electrode geometric area0.2 x 0.2 cm^-2; stated geometric area A is 0.04 cm^2Text
Exact Reported
3-4 · Electrochemical measurements; Electrochemical determination of glucose