Capacitance response to ethanol
Co-TCPP device without mobile metal ions on conductive glass · Electrode
Response to 1 uL ethanol compared with Co-TCPP IC-MOF sensor.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| No-mobile-ion control capacitance | approximately 8-10 pF baseline from Figure 6b | — | visual range approximately 8-10 pF | Figure Axis Approximate | 6 · Results and Discussion · Figure 6b |
| No-mobile-ion control response to 1 uL ethanol | negligible response | — | — | Qualitative Qualitative | 5 · Results and Discussion · Figure 6b |