Seebeck coefficient measurement.
Rectangular Ni3HBC pellet for electrical and thermal transport · Pellet
High-vacuum cryostat; Seebeck voltage and thermocouple voltages measured with Keithley 2182a nanovoltmeter; temperature gradient from an ohmic heater.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Seebeck coefficient at 302 KMarked as a best value within this paper | 99.0 microV K-1 at 302 K | — | — | Text Exact Reported | 2060 · Transport properties · Figure 4c |
| Seebeck temperature dependence | nearly constant across the measured temperature range | — | — | Text Qualitative | 2060 · Transport properties · Figure 4c |