chemiresistive sensing of NO and NH3
Bi(HHTP) chemiresistor on 10 um gap gold electrodes · Electrode
1.0 V applied; dry N2; 5-40 ppm NO/NH3 for 15 min; 0.5 L/min N2 flow; room temperature
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| NH3 concentration-response slope | y = 0.54x + 32, R2 = 0.78 | — | — | Figure Axis Approximate | 60312 · Figure 5c · Figure 5 |
| NH3 initial-rate slope | y = 0.44x - 0.11, R2 = 0.98 | — | — | Figure Axis Approximate | 60312 · Figure 5d · Figure 5 |
| NO concentration-response slope | y = -1.4x + 2.2, R2 = 0.95 | — | — | Figure Axis Approximate | 60312 · Figure 5c · Figure 5 |
| NO initial-rate slope | y = -0.40x - 0.81, R2 = 0.93 | — | — | Figure Axis Approximate | 60312 · Figure 5d · Figure 5 |
| NH3 limit of detectionMarked as a best value within this paper | 0.29 ppm | — | — | SI Table Exact Reported | S41-S42 · Limits of Detection Calculation · Table S4 |
| NH3 response at 40 ppm after 15 minMarked as a best value within this paper | 58.4 +/- 2% -DeltaG/G0 | — | ± 2% | Text Exact Reported | 60313 · Chemiresistive Sensing Response · Figure 5 |
| NO limit of detectionMarked as a best value within this paper | 0.15 ppm | — | — | SI Table Exact Reported | S41-S42 · Limits of Detection Calculation · Table S4 |
| NO response at 40 ppm after 15 minMarked as a best value within this paper | -54.8 +/- 6% -DeltaG/G0 | — | ± 6% | Text Exact Reported | 60313 · Chemiresistive Sensing Response · Figure 5 |