SEM and TEM morphology
Ni3HHTP2 film working electrode on Au/BNC · Electrode
SEM/TEM used to image BNC membrane and Ni3HHTP2 film electrode; JEOL JSM-7600 SEM and JEOL 2010 HR/UHR TEM listed in SI.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| BNC membrane pore morphology | Micrometer-sized pores randomly distributed in cellulose network | — | — | Text Qualitative | 2 · Results and Discussions · Figure 1c; Figure S3 |
| Ni3HHTP2 working-electrode morphology | Randomly oriented Ni3HHTP2 nanorods | — | — | Text Qualitative | 2 · Results and Discussions · Figure 1e |