Porosity — Wet-Adhesive On-Skin Sensors Based on Metal–Organic Frameworks for Wireless Monitoring of Metabolites in Sweat

Measurement evidence

Porosity

Wet-Adhesive On-Skin Sensors Based on Metal–Organic Frameworks for Wireless Monitoring of Metabolites in Sweat · Yang X., Yi J., Wang T. et al. · Advanced Materials · 2022 · 2201768

1 measurement group · 2 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

N2 sorption / BET and BJH pore-size analysis

Activated Ni3HHTP2 powder · Powder

ASAP 2460; powders solvent exchanged with acetone, heated at 80 C under vacuum overnight, outgassed at 80 C for 10 h; N2 isotherm at 77 K and 1 bar.

Temperature
77
Atmosphere
N2
Geometry
Activated powder
Context
Pristine target cMOF porosity
Measurement source
S4; S11 · Gas sorption measurements · Figure S6
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
BET surface areaMarked as a best value within this paper599.74 m2 g^-1Text
Exact Reported
2 · Results and Discussions · Figure S6
Average pore diameterMarked as a best value within this paper1.3 nmText
Exact Reported
2 · Results and Discussions · Figure S6