Bismuth-based conductive MOF/COF hybrids enable efficient electrochemical heavy metal ion quantification · Shangguan N., Liu Y., Fan X. et al. · Microchemical Journal · 2026 · 117458

4 measurement groups · 8 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Cyclic voltammetry

Bi-HHTP/COF/GCE · Electrode

0.1 M KCl containing 5 mM [Fe(CN)6]3-/4- redox probe; anodic peak current and EASA.

Context
target electrode
Measurement source
6 · 3.2 · Fig. S2A-B
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CV anodic peak currentMarked as a best value within this paper147.2 uAText
Exact Reported
5-6 · 3.2 · Fig. S2A
electrochemical active surface areaMarked as a best value within this paper0.122 cm2Text
Exact Reported
6 · 3.2 · Fig. S2B

Cyclic voltammetry

Bi-HHTP/GCE · Electrode

0.1 M KCl containing 5 mM [Fe(CN)6]3-/4- redox probe; anodic peak current and EASA.

Context
Bi-HHTP-only electrode control
Measurement source
6 · 3.2 · Fig. S2A-B
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CV anodic peak current132.6 uAText
Exact Reported
5-6 · 3.2 · Fig. S2A
electrochemical active surface area0.111 cm2Text
Exact Reported
6 · 3.2 · Fig. S2B

Cyclic voltammetry

COF/GCE · Electrode

0.1 M KCl containing 5 mM [Fe(CN)6]3-/4- redox probe; anodic peak current and EASA.

Context
COF-only electrode control
Measurement source
5-6 · 3.2 · Fig. S2A-B
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CV anodic peak current124.7 uAText
Exact Reported
5-6 · 3.2 · Fig. S2A
electrochemical active surface area0.101 cm2Text
Exact Reported
6 · 3.2 · Fig. S2B

Cyclic voltammetry

bare GCE · Electrode

0.1 M KCl containing 5 mM [Fe(CN)6]3-/4- redox probe; anodic peak current and EASA.

Context
bare control
Measurement source
5-6 · 3.2 · Fig. S2A-B
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CV anodic peak current94.5 uAText
Exact Reported
5-6 · 3.2 · Fig. S2A
electrochemical active surface area0.092 cm2Text
Exact Reported
6 · 3.2 · Fig. S2B