two-probe dc current-voltage conductivity
compound 1 pressed pellet · Pellet
Ambient-temperature pressed pellet conductivity in dinitrogen-filled glovebox using home-built press and Keithley 6517B electrometer
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| ambient-temperature conductivity of compound 1Marked as a best value within this paper | sigma = 1.4(7) x 10^-2 S/cm | 0.014 S/cm | (7) x 10^-2 S/cm | Text Exact Reported | 7 · Electrical Conductivity · Figure 8; Figure S12 |