Electrical Transport — Synthesis of Stable 2D Conductive Lanthanide Organic Frameworks (Lu-HHTP) for High-Performance Humidity Sensors

Measurement evidence

Electrical Transport

Synthesis of Stable 2D Conductive Lanthanide Organic Frameworks (Lu-HHTP) for High-Performance Humidity Sensors · Jiang S., Mo X., Zhao X. et al. · Analysis and Sensing · 2024 · e202400024

1 measurement group · 2 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

two-contact probe electrical transport, linear I-V

Pressed Lu-HHTP pellet · Pellet

Pressed pellet measured at 302 K using a home-built two-point probe setup; powder compressed between copper nails under 0.4 GPa; voltage generally swept between -2 and +2 V

Temperature
302
Geometry
pressed pellet between copper-nail current collectors
Context
pristine Lu-HHTP pressed pellet
Measurement source
4 · Experimental Section - Electrical conductivity measurements · Figure S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Pressed-pellet electrical conductivityMarked as a best value within this paper1.7 x 10^-4 mS/cm1.7e-7 S cm-1Text
Exact Reported
3 · Results and Discussion - Synthesis and Characterization · Figure S4
I-V linearitylinear I-V curveCaption
Qualitative
6 · 2. Supplementary Figures and Tables · Figure S4