EDX elemental analysis and ICP-MS
GTUB3 single crystals / crystal powder · Single Crystal
EDX elemental mapping plus ICP-MS elemental ratio determination using Perkin Elmer standard solutions and internal standards.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| ICP-MS Cu mass fraction | about 6.2% | — | — | Text Approximate | S15 · 8. ICP-MS Measurements |
| ICP-MS Cu concentration | 62058.22 ppm | — | — | Text Exact Reported | S15 · 8. ICP-MS Measurements |
| ICP-MS P mass fraction | about 12.1% | — | — | Text Approximate | S15 · 8. ICP-MS Measurements |
| ICP-MS P concentration | 121997.15 ppm | — | — | Text Exact Reported | S15 · 8. ICP-MS Measurements |
| ICP-MS Zn mass fraction | about 6.4% | — | — | Text Approximate | S15 · 8. ICP-MS Measurements |
| ICP-MS Zn concentration | 64698.23 ppm | — | — | Text Exact Reported | S15 · 8. ICP-MS Measurements |
| EDS elemental distribution | even distribution of constituent elements | — | — | Caption Qualitative | S6 · Figure S4 · Figure S4 |