Two-probe I-V temperature-dependent conductivity with Keithley 4200 source meter.

Cu3(HHTP)2-40C thin-film device · Electrode

I-V curves measured from 200 K to 300 K; log sigma plotted versus 1/T.

Temperature
200-300
Geometry
Two-probe Au electrodes; schematic shows interdigitated Au electrodes with 100 um gap and 1000 um length.
Context
Pristine Cu3(HHTP)2-40C thin film.
Measurement source
SI p.10 · Figure S6 caption and text · Figure S6
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Activation energy from log sigma vs 1/T0.16 eVText
Exact Reported
SI p.10 · Figure S6 text · Figure S6d
Ohmic contact assessmentlinear and zero-drift I-V curves indicate good ohmic contactQualitative
Qualitative
SI p.10 · Figure S6 text · Figure S6c
Room-temperature conductivityMarked as a best value within this paper0.02 S cm-1Text
Rounded Reported
SI p.10 · Figure S6 text · Figure S6