Other — Electronic Doping of Metal-Organic Frameworks for High-Performance Flexible Micro-Supercapacitors

Measurement evidence

Other

Electronic Doping of Metal-Organic Frameworks for High-Performance Flexible Micro-Supercapacitors · He Y., Yang S., Fu Y. et al. · Small Structures · 2021 · 2000095

4 measurement groups · 4 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

mass loading from device fabrication

TCNQ@Cu3(BTC)2 thin film on Cu foil · Thin Film

Active-material mass loading reported for resulting MOF/doped-MOF thin-film samples.

Geometry
Cu-foil-supported thin film
Context
MOF thin-film/device fabrication
Measurement source
Experimental Section, Device fabrication
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
active material mass loadingabout 1 mg cm^-2Text
Approximate
Experimental Section, Device fabrication

TGA

BQ@Cu3(BTC)2 thin film on Cu foil · Thin Film

TGA on Perkin-Elmer Pyris 1 in N2 atmosphere at 10 C min^-1; guest weight ratio estimated from Figure S8.

Context
guest loading
Measurement source
3 · Experimental Section, Characterization · Figure S8
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
BQ weight ratio in doped Cu3(BTC)210.6 wt%Text
Exact Reported
3 · Results and Discussion · Figure S8

TGA

PMDI@Cu3(BTC)2 thin film on Cu foil · Thin Film

TGA on Perkin-Elmer Pyris 1 in N2 atmosphere at 10 C min^-1; guest weight ratio estimated from Figure S8.

Context
guest loading
Measurement source
3 · Experimental Section, Characterization · Figure S8
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
PMDI weight ratio in doped Cu3(BTC)212.5 wt%Text
Exact Reported
3 · Results and Discussion · Figure S8

TGA

TCNQ@Cu3(BTC)2 thin film on Cu foil · Thin Film

TGA on Perkin-Elmer Pyris 1 in N2 atmosphere at 10 C min^-1; guest weight ratio estimated from Figure S8.

Context
guest loading
Measurement source
3 · Experimental Section, Characterization · Figure S8
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
TCNQ weight ratio in doped Cu3(BTC)217.9 wt%Text
Exact Reported
3 · Results and Discussion · Figure S8