MFC COD removal
Ni-Co-CAT/carbon black/PTFE air cathode · Electrode
PBS buffer used as COD influent; MFC effluent collected when reactor voltage decreased to 0.05 V; standard curve and influent/effluent absorbance measured.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| carbon black MFC COD removal rate | 57.01% | — | — | Figure Axis Rounded Reported | 754 · 2.3 · Figure 6 |
| carbon black MFC effluent COD | 143.5 mg/L | — | — | Text Exact Reported | 753 · 2.3 · Figure 6 |
| MFC influent COD | 333.8 mg/L | — | — | Text Exact Reported | 753 · 2.3 · Figure 6 |
| Ni-CAT MFC COD removal rate | 43.78% | — | — | Figure Axis Rounded Reported | 754 · 2.3 · Figure 6 |
| Ni-CAT MFC effluent COD | 187.7 mg/L | — | — | Text Exact Reported | 753 · 2.3 · Figure 6 |
| Ni-Co-CAT MFC COD removal rateMarked as a best value within this paper | 72.49% | — | — | Text Exact Reported | 753-754 · 2.3; 3 · Figure 6 |
| Ni-Co-CAT MFC effluent CODMarked as a best value within this paper | 91.8 mg/L | — | — | Text Exact Reported | 753 · 2.3 · Figure 6 |
| Pt/C MFC COD removal rate | 49.52% | — | — | Figure Axis Rounded Reported | 754 · 2.3 · Figure 6 |
| Pt/C MFC effluent COD | 168.5 mg/L | — | — | Text Exact Reported | 753 · 2.3 · Figure 6 |