Electrochemistry Application — Preparation of Bimetallic Conductive Metal-organic Framework Material Ni/Co-CAT for Electrocatalytic Oxygen Reduction 双金属导电金属有机框架材料 Ni/Co-CAT 的制备及其氧还原催化性能研究

Measurement evidence

Electrochemistry Application

Preparation of Bimetallic Conductive Metal-organic Framework Material Ni/Co-CAT for Electrocatalytic Oxygen Reduction 双金属导电金属有机框架材料 Ni/Co-CAT 的制备及其氧还原催化性能研究 · Geng Y., Lin X., Sun Y. et al. · Acta Chimica Sinica · 2022 · 748-755

7 measurement groups · 31 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

MFC COD removal

Ni-Co-CAT/carbon black/PTFE air cathode · Electrode

PBS buffer used as COD influent; MFC effluent collected when reactor voltage decreased to 0.05 V; standard curve and influent/effluent absorbance measured.

Atmosphere
air cathode; no aeration stated
Geometry
single-chamber MFC with catalyst-modified carbon-cloth air cathode
Context
composite cathodes containing Ni-CAT or Ni-Co-CAT plus carbon black/PTFE; carbon black and Pt/C controls
Measurement source
753-754 · 2.3 · Figure 6
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
carbon black MFC COD removal rate57.01%Figure Axis
Rounded Reported
754 · 2.3 · Figure 6
carbon black MFC effluent COD143.5 mg/LText
Exact Reported
753 · 2.3 · Figure 6
MFC influent COD333.8 mg/LText
Exact Reported
753 · 2.3 · Figure 6
Ni-CAT MFC COD removal rate43.78%Figure Axis
Rounded Reported
754 · 2.3 · Figure 6
Ni-CAT MFC effluent COD187.7 mg/LText
Exact Reported
753 · 2.3 · Figure 6
Ni-Co-CAT MFC COD removal rateMarked as a best value within this paper72.49%Text
Exact Reported
753-754 · 2.3; 3 · Figure 6
Ni-Co-CAT MFC effluent CODMarked as a best value within this paper91.8 mg/LText
Exact Reported
753 · 2.3 · Figure 6
Pt/C MFC COD removal rate49.52%Figure Axis
Rounded Reported
754 · 2.3 · Figure 6
Pt/C MFC effluent COD168.5 mg/LText
Exact Reported
753 · 2.3 · Figure 6

cyclic voltammetry (CV)

Ni-Co-CAT/carbon black/PTFE air cathode · Electrode

Three-electrode system in 50 mmol/L phosphate buffer; electrode clip working-electrode base, graphite rod counter electrode, Hg/HgO reference; potential window -0.6 to 0.6 V; scan rate 0.01 V/s.

Geometry
air-cathode catalyst on carbon cloth
Context
composite cathodes containing Ni-CAT or Ni-Co-CAT plus carbon black/PTFE; carbon black and Pt/C controls
Measurement source
750, 755 · 2.2; 4.5 · Figure 4a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
carbon black anodic peak potential0.15 VText
Exact Reported
750 · 2.2 · Figure 4a
CV cathodic peak potential range-0.6 to -0.5 Vrange -0.6 to -0.5 VText
Range
750 · 2.2 · Figure 4a

electrochemical impedance spectroscopy (EIS)

Ni-Co-CAT/carbon black/PTFE air cathode · Electrode

Three-electrode system in 50 mmol/L phosphate buffer; amplitude 5.0 mV; frequency range 0.01-100 kHz; test potential open-circuit voltage; fitted with ZSimDemo 3.30d equivalent circuit.

Geometry
air-cathode catalyst on carbon cloth
Context
composite cathodes containing Ni-CAT or Ni-Co-CAT plus carbon black/PTFE; carbon black and Pt/C controls
Measurement source
752, 755 · 2.2; 4.5 · Figure 4c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
carbon black fitted ohmic internal resistanceMarked as a best value within this paper9.23 ΩText
Exact Reported
752 · 2.2 · Figure 4c
Ni-CAT fitted ohmic internal resistance20.12 ΩText
Exact Reported
752 · 2.2 · Figure 4c
Ni-Co-CAT fitted ohmic internal resistance26.28 ΩText
Exact Reported
752 · 2.2 · Figure 4c
Pt/C fitted ohmic internal resistance9.58 ΩText
Exact Reported
752 · 2.2 · Figure 4c

linear sweep voltammetry (LSV)

Ni-Co-CAT/carbon black/PTFE air cathode · Electrode

Three-electrode system in 50 mmol/L phosphate buffer; potential window -0.6 to 0.6 V; scan rate 0.01 V/s.

Geometry
air-cathode catalyst on carbon cloth
Context
composite cathodes containing Ni-CAT or Ni-Co-CAT plus carbon black/PTFE; carbon black and Pt/C controls
Measurement source
750, 755 · 2.2; 4.5 · Figure 4b
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Ni-CAT half-wave potential-0.45 VText
Exact Reported
752 · 2.2 · Figure 4b
Ni-CAT limiting current density2.18 mA/cm2Text
Exact Reported
750, 754 · 2.2; 3 · Figure 4b
Ni-Co-CAT half-wave potential-0.46 VText
Exact Reported
752 · 2.2 · Figure 4b
Ni-Co-CAT limiting current densityMarked as a best value within this paper2.84 mA/cm2Text
Exact Reported
750, 754 · 2.2; 3 · Figure 4b

single-chamber air-cathode microbial fuel cell power-density and polarisation tests

Ni-Co-CAT/carbon black/PTFE air cathode · Electrode

28 mL single-chamber air-cathode MFC; anode carbon cloth pretreated with acetone; 30 ℃ constant-temperature dark box; inoculum from MFC effluent run >2 months mixed with buffer 1:10; started with 1000 Ω external resistor; power-density test after 1 h open circuit, 50-10000 Ω loads from high to low, 30 min stabilisation per load.

Temperature
303.15
Atmosphere
air cathode; no aeration stated
Geometry
single-chamber MFC with catalyst-modified carbon-cloth air cathode
Context
composite cathodes containing Ni-CAT or Ni-Co-CAT plus carbon black/PTFE; carbon black and Pt/C controls
Measurement source
752-754 · 2.3; 4.3; 4.4 · Figure 5a,b
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
carbon black MFC maximum power density90 mW/m2Text
Exact Reported
752 · 2.3 · Figure 5a
Ni-CAT MFC maximum power density130 mW/m2Text
Exact Reported
752 · 2.3 · Figure 5a
Ni-Co-CAT MFC maximum power density190 mW/m2Text
Exact Reported
752 · 2.3 · Figure 5a
Pt/C MFC maximum power densityMarked as a best value within this paper220 mW/m2Text
Exact Reported
752 · 2.3 · Figure 5a

MFC output voltage time-course

Ni-Co-CAT/carbon black/PTFE air cathode · Electrode

MPS-010602 data logger recorded output voltage every 1 min over 30 days after reactor start.

Temperature
303.15
Atmosphere
air cathode; no aeration stated
Geometry
single-chamber MFC with catalyst-modified carbon-cloth air cathode
Context
composite cathodes containing Ni-CAT or Ni-Co-CAT plus carbon black/PTFE; carbon black and Pt/C controls
Measurement source
753-755 · 2.3; 4.5 · Figure 5c-f
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
carbon black MFC maximum output voltageabout 0.23 VText
Approximate
753 · 2.3 · Figure 5e
Ni-CAT MFC maximum output voltageabout 0.26 VText
Approximate
753 · 2.3 · Figure 5c
Ni-Co-CAT MFC maximum output voltageabout 0.31 V; 310 mV310 mVText
Approximate
748, 753 · Abstract; 2.3 · Figure 5d
Pt/C MFC maximum output voltageMarked as a best value within this paperabout 0.32 VText
Approximate
753 · 2.3 · Figure 5f

Tafel analysis from LSV

Ni-Co-CAT/carbon black/PTFE air cathode · Electrode

Tafel curves calculated from LSV using η = a + b lg i; current density in mA/cm2; Tafel slope in mV/dec.

Geometry
air-cathode catalyst on carbon cloth
Context
composite cathodes containing Ni-CAT or Ni-Co-CAT plus carbon black/PTFE; carbon black and Pt/C controls
Measurement source
752, 755 · 2.2; 4.5 · Figure 4d
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
carbon black Tafel slope196 mV/decText
Exact Reported
752 · 2.2 · Figure 4d
Ni-CAT Tafel slope173 mV/decText
Exact Reported
752 · 2.2 · Figure 4d
Ni-Co-CAT Tafel slope146 mV/decText
Exact Reported
752 · 2.2 · Figure 4d
Pt/C Tafel slopeMarked as a best value within this paper128 mV/decFigure Axis
Rounded Reported
752 · 2.2 · Figure 4d