high-resolution powder X-ray diffraction (XRD; Smartlab, Rigaku)
activated PCN-222 powder · Powder
Experimental powder XRD compared with simulated PCN-222 pattern.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| PCN-222 phase assignment | experimental powder XRD well matches simulated PCN-222 pattern | — | — | Text Qualitative | 4 · 3. Results and discussion · Fig. 2d |
| PCN-222 XRD peak position | 2.4 deg 2theta | — | — | Text Rounded Reported | 4 · 3. Results and discussion · Fig. 2d |
| PCN-222 XRD peak position | 4.7 deg 2theta | — | — | Text Rounded Reported | 4 · 3. Results and discussion · Fig. 2d |
| PCN-222 XRD peak position | 7.0 deg 2theta | — | — | Text Rounded Reported | 4 · 3. Results and discussion · Fig. 2d |
| PCN-222 XRD peak position | 9.6 deg 2theta | — | — | Text Rounded Reported | 4 · 3. Results and discussion · Fig. 2d |