PXRD with Cu Kalpha radiation; simulated patterns compared for AA/eclipsed and AB/staggered stacking.
truxone-Cu MOF powder/nanosheets · Powder
RIGAKU SMART LAB, Cu target, lambda = 1.5406 Angstrom, 9 kW, 45 kV, 200 mA.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| PXRD (001) reflection | 2theta = 27.40 deg | — | — | Text Exact Reported | p004 / article p.12693 · Results and Discussion · Figure 1b |
| PXRD (100) reflection | 2theta = 3.86 deg | — | — | Text Exact Reported | p003 / article p.12692 · Results and Discussion · Figure 1b |
| hexagonal unit-cell a and b | a = b = 26.6 Angstrom | — | — | Text Exact Reported | p004 / article p.12693 · Results and Discussion · Figure 1 |
| hexagonal unit-cell c | c = 3.3 Angstrom | — | — | Text Exact Reported | p004 / article p.12693 · Results and Discussion · Figure 1 |