Electrochemistry Application — Synthesis of Tostadas-Shaped Metal-Organic Frameworks for Remitting Capacity Fading of Li-Ion Batteries

Measurement evidence

Electrochemistry Application

Synthesis of Tostadas-Shaped Metal-Organic Frameworks for Remitting Capacity Fading of Li-Ion Batteries · Cai Y., Wang W., Cao X. et al. · Advanced Functional Materials · 2022 · 2109927

13 measurement groups · 42 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

cyclic voltammetry

NHM composite working electrode · Electrode

Initial three cycles; 0.01-3.0 V; 0.1 mV s-1.

Atmosphere
Ar glovebox for assembly
Geometry
coin cell anode
Context
NHM composite electrode
Measurement source
p005-p006 · Results and Discussion · Figure 4a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
NHM anodic oxidation peak1.01 V vs Li/Li+Text
Exact Reported
p005 · Results and Discussion · Figure 4a
NHM anodic oxidation peak2.17 V vs Li/Li+Text
Exact Reported
p005 · Results and Discussion · Figure 4a
NHM cathodic reduction peak0.42 V vs Li/Li+Text
Exact Reported
p005 · Results and Discussion · Figure 4a
NHM cathodic reduction peak1.4 V vs Li/Li+Text
Approximate
p005 · Results and Discussion · Figure 4a

CV at variable scan rates and capacitive contribution analysis

NHM composite working electrode · Electrode

Scan rates 0.2-1.2 mV s-1; b-value analysis and capacitive/diffusion separation.

Geometry
coin cell anode
Context
NHM composite electrode
Measurement source
p006-p007 · Results and Discussion · Figure 5a-d
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
NHM b-value for anodic peaksMarked as a best value within this paper0.59Text
Exact Reported
p006-p007 · Results and Discussion · Figure 5c
NHM b-value for cathodic peaksMarked as a best value within this paper0.57Text
Exact Reported
p006-p007 · Results and Discussion · Figure 5c
NHM capacitive contribution at 0.2 mV s-147% at 0.2 mV s-1Text
Exact Reported
p006-p007 · Results and Discussion · Figure 5d
NHM capacitive contribution at 0.4 mV s-152% at 0.4 mV s-1Text
Exact Reported
p006-p007 · Results and Discussion · Figure 5d
NHM capacitive contribution at 0.6 mV s-155% at 0.6 mV s-1Text
Exact Reported
p006-p007 · Results and Discussion · Figure 5d
NHM capacitive contribution at 0.8 mV s-176% at 0.8 mV s-1Text
Exact Reported
p006-p007 · Results and Discussion · Figure 5d
NHM capacitive contribution at 1.0 mV s-182% at 1.0 mV s-1Text
Exact Reported
p006-p007 · Results and Discussion · Figure 5d
NHM capacitive contribution at 1.2 mV s-1Marked as a best value within this paper88% at 1.2 mV s-1Text
Exact Reported
p006-p007 · Results and Discussion · Figure 5d

CV at variable scan rates and b-value analysis

NHP composite working electrode · Electrode

Scan rates 0.2-1.2 mV s-1.

Geometry
coin cell anode
Context
NHP composite control electrode
Measurement source
p006 · Results and Discussion · Figure 5c; Figure S14
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
NHP b-value for anodic peaks0.39Text
Exact Reported
p006-p007 · Results and Discussion · Figure 5c
NHP b-value for cathodic peaks0.38Text
Exact Reported
p006-p007 · Results and Discussion · Figure 5c

CV at variable scan rates and b-value analysis

NHS composite working electrode · Electrode

Scan rates 0.2-1.2 mV s-1.

Geometry
coin cell anode
Context
NHS composite control electrode
Measurement source
p006 · Results and Discussion · Figure 5c; Figure S14
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
NHS b-value for anodic peaks0.48Text
Exact Reported
p006-p007 · Results and Discussion · Figure 5c
NHS b-value for cathodic peaks0.47Text
Exact Reported
p006-p007 · Results and Discussion · Figure 5c

galvanostatic cycling

NHM composite working electrode · Electrode

2032 coin cell versus Li/Li+; 0.01-3.0 V; 0.1 A g-1 for 100 cycles.

Atmosphere
Ar glovebox for assembly
Geometry
coin cell anode, Li metal counter/reference
Context
NHM/Super-P/PVDF electrode using pristine NHM active material
Measurement source
p004-p005 · Results and Discussion · Figure 3a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
NHM capacity after 100 cycles at 0.1 A g-1Marked as a best value within this paper1280 mA h g-1Text
Exact Reported
p004 · Results and Discussion · Figure 3a
NHM first-cycle discharge capacity at 0.1 A g-1Marked as a best value within this paper1787 mA h g-1Text
Exact Reported
p004 · Results and Discussion · Figure 3a

galvanostatic cycling

NHP composite working electrode · Electrode

2032 coin cell versus Li/Li+; 0.01-3.0 V; 0.1 A g-1 for 100 cycles.

Atmosphere
Ar glovebox for assembly
Geometry
coin cell anode
Context
NHP/Super-P/PVDF control electrode
Measurement source
p004 · Results and Discussion · Figure 3a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
NHP capacity after 100 cycles at 0.1 A g-1105 mA h g-1Text
Exact Reported
p004 · Results and Discussion · Figure 3a
NHP first-cycle discharge capacity at 0.1 A g-1397 mA h g-1Text
Exact Reported
p004 · Results and Discussion · Figure 3a

galvanostatic cycling

NHS composite working electrode · Electrode

2032 coin cell versus Li/Li+; 0.01-3.0 V; 0.1 A g-1 for 100 cycles.

Atmosphere
Ar glovebox for assembly
Geometry
coin cell anode
Context
NHS/Super-P/PVDF control electrode
Measurement source
p004 · Results and Discussion · Figure 3a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
NHS capacity after 100 cycles at 0.1 A g-1497 mA h g-1Text
Exact Reported
p004 · Results and Discussion · Figure 3a
NHS first-cycle discharge capacity at 0.1 A g-1946 mA h g-1Text
Exact Reported
p004 · Results and Discussion · Figure 3a

electrochemical impedance spectroscopy (EIS)

NHM composite working electrode · Electrode

10 mHz to 1 MHz, 10 mV AC amplitude; before cycling and after selected cycles.

Geometry
coin cell anode; equivalent circuit shown in figure
Context
NHM, NHS, and NHP composite electrodes
Measurement source
p006 · Results and Discussion · Figure 4b-c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Reported charge-transfer resistance orderRct(NHS) slightly less than Rct(NHM), and Rct(NHM) less than Rct(NHP)Qualitative
Qualitative
p005 · Results and Discussion · Figure 4b
Approximate pre-cycling Rct for NHMabout 105 ohm from Figure 4bFigure Axis
Approximate
p006 · Results and Discussion · Figure 4b
Approximate pre-cycling Rct for NHPabout 150 ohm from Figure 4bFigure Axis
Approximate
p006 · Results and Discussion · Figure 4b
Approximate pre-cycling Rct for NHSMarked as a best value within this paperabout 70 ohm from Figure 4bFigure Axis
Approximate
p006 · Results and Discussion · Figure 4b

long-term galvanostatic cycling

NHM composite working electrode · Electrode

High rate 1 A g-1 for 1000 cycles.

Atmosphere
Ar glovebox for assembly
Geometry
coin cell anode
Context
NHM composite electrode
Measurement source
p005 · Results and Discussion · Figure 3c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
NHM long-term capacity at 1 A g-1 (1000 cycles)Marked as a best value within this paper392 mA h g-1Text
Exact Reported
p005 · Results and Discussion · Figure 3c
NHM long-term capacity at 1 A g-1 (200 cycles)576 mA h g-1Text
Exact Reported
p005 · Results and Discussion · Figure 3c
NHM long-term capacity at 1 A g-1 (0 cycles)414 mA h g-1Text
Exact Reported
p005 · Results and Discussion · Figure 3c

rate capability galvanostatic cycling

NHM composite working electrode · Electrode

Current density stepped from 0.1 to 2 A g-1 and back to 0.1 A g-1.

Atmosphere
Ar glovebox for assembly
Geometry
coin cell anode
Context
NHM composite electrode
Measurement source
p004 · Results and Discussion · Figure 3b
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
NHM reversible capacity at 0.1 A g-1Marked as a best value within this paper950 mA h g-1 at 0.1 A g-1Text
Exact Reported
p004 · Results and Discussion · Figure 3b
NHM reversible capacity at 0.2 A g-1754 mA h g-1 at 0.2 A g-1Text
Exact Reported
p004 · Results and Discussion · Figure 3b
NHM reversible capacity at 0.5 A g-1572 mA h g-1 at 0.5 A g-1Text
Exact Reported
p004 · Results and Discussion · Figure 3b
NHM reversible capacity at 2.0 A g-1366 mA h g-1 at 2.0 A g-1Text
Exact Reported
p004 · Results and Discussion · Figure 3b
NHM capacity after returning to 0.1 A g-1800 mA h g-1Text
Exact Reported
p004 · Results and Discussion · Figure 3b

rate capability galvanostatic cycling

NHP composite working electrode · Electrode

Current density stepped from 0.1 to 2 A g-1.

Atmosphere
Ar glovebox for assembly
Geometry
coin cell anode
Context
NHP composite control electrode
Measurement source
p004 · Results and Discussion · Figure 3b
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
NHP reversible capacity at 0.1 A g-1537 mA h g-1Text
Exact Reported
p004 · Results and Discussion · Figure 3b
NHP reversible capacity at 2 A g-184 mA h g-1Text
Exact Reported
p004 · Results and Discussion · Figure 3b

rate capability galvanostatic cycling

NHS composite working electrode · Electrode

Current density stepped from 0.1 to 2 A g-1.

Atmosphere
Ar glovebox for assembly
Geometry
coin cell anode
Context
NHS composite control electrode
Measurement source
p004 · Results and Discussion · Figure 3b
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
NHS reversible capacity at 0.1 A g-1716 mA h g-1Text
Exact Reported
p004 · Results and Discussion · Figure 3b
NHS reversible capacity at 2 A g-1129 mA h g-1Text
Exact Reported
p004 · Results and Discussion · Figure 3b

literature comparison table entry

NHM composite working electrode · Electrode

Table S1 comparison of anodes; NHM row from this work.

Geometry
coin cell anode
Context
NHM electrode compared with literature anodes
Measurement source
p006-p007 · Table S1 · Table S1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
NHM Table S1 charge capacity1334 mA h g-1SI Table
Exact Reported
p006 · Table S1 · Table S1
NHM Table S1 discharge capacity1787 mA h g-1SI Table
Exact Reported
p006 · Table S1 · Table S1
NHM Table S1 capacity after 100 cyclesMarked as a best value within this paper1280 mA h g-1SI Table
Exact Reported
p006 · Table S1 · Table S1
NHM Table S1 capacity after 1000 cyclesMarked as a best value within this paper390 mA h g-1SI Table
Rounded Reported
p006 · Table S1 · Table S1