Spectroscopy — Synthesis of Tostadas-Shaped Metal-Organic Frameworks for Remitting Capacity Fading of Li-Ion Batteries

Measurement evidence

Spectroscopy

Synthesis of Tostadas-Shaped Metal-Organic Frameworks for Remitting Capacity Fading of Li-Ion Batteries · Cai Y., Wang W., Cao X. et al. · Advanced Functional Materials · 2022 · 2109927

4 measurement groups · 15 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

FTIR spectroscopy

NHM; Tostadas-shaped Ni-HITP assembly · Powder

4000-400 cm-1 transmission mode in SI; peaks assigned for Ni-HITP samples.

Geometry
transmission FTIR
Context
pristine Ni-HITP samples
Measurement source
p003 · Results and Discussion · Figure S7
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
FTIR band: C-N / N-H vibration1300 cm-1Text
Exact Reported
p003 · Results and Discussion · Figure S7
FTIR band: C-N / N-H vibration1620 cm-1Text
Exact Reported
p003 · Results and Discussion · Figure S7
FTIR band: N-H stretching3180 cm-1Text
Exact Reported
p003 · Results and Discussion · Figure S7
FTIR band: N-H stretching3345 cm-1Text
Exact Reported
p003 · Results and Discussion · Figure S7

Raman spectroscopy

NHM; Tostadas-shaped Ni-HITP assembly · Powder

473 nm Raman; 100-3000 cm-1; 2 s runs with three accumulations.

Geometry
Horiba Raman spectrophotometer
Context
pristine Ni-HITP powders
Measurement source
p003 · Results and Discussion · Figure S9
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Raman D/G defect-order comparisonMarked as a best value within this paperi(D)/i(G)NHM > i(D)/i(G)NHS = i(D)/i(G)NHPQualitative
Qualitative
p003 · Results and Discussion · Figure S9

thermogravimetric analysis (TGA)

NHM; Tostadas-shaped Ni-HITP assembly · Powder

N2 atmosphere, 10 C min-1 heating rate; NHS, NHP, NHM compared.

Atmosphere
N2
Geometry
Pyris Diamond TG-DTA
Context
pristine Ni-HITP powders
Measurement source
p003 · Results and Discussion · Figure S8
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Apparent TGA weight-loss onsetbegan at 275 CText
Exact Reported
p003 · Results and Discussion · Figure S8

X-ray photoelectron spectroscopy (XPS)

NHM; Tostadas-shaped Ni-HITP assembly · Powder

High-resolution Ni 2p and N 1s on NHM, NHS, and NHP; C 1s in SI Figure S10.

Geometry
ThermoFisher Nexsa stated in SI
Context
pristine Ni-HITP powders
Measurement source
p003-p004 · Results and Discussion · Figure 2a-b; Figure S10
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Active-site content N-Ni/N-C ratio for NHMMarked as a best value within this paper1.11Text
Exact Reported
p004 · Results and Discussion · Figure 2a-b
Active-site content N-Ni/N-C ratio for NHP1.03Text
Exact Reported
p004 · Results and Discussion · Figure 2a-b
Active-site content N-Ni/N-C ratio for NHS1.09Text
Exact Reported
p004 · Results and Discussion · Figure 2a-b
N-C399.0 eV (also resolved near 398.98 eV)Text
Exact Reported
p003-p004 · Results and Discussion · Figure 2a-b
N-Ni400.2 eV (also resolved near 400.18 eV)Text
Exact Reported
p003-p004 · Results and Discussion · Figure 2a-b
Ni 2p1/2871.94 eVText
Exact Reported
p003-p004 · Results and Discussion · Figure 2a-b
Ni 2p1/2 satellite878.30 eVText
Exact Reported
p003-p004 · Results and Discussion · Figure 2a-b
Ni 2p3/2854.36 eVText
Exact Reported
p003-p004 · Results and Discussion · Figure 2a-b
Ni 2p3/2 satellite860.30 eVText
Exact Reported
p003-p004 · Results and Discussion · Figure 2a-b