Spectroscopy — Encapsulating metal organic framework into hollow mesoporous carbon sphere as efficient oxygen bifunctional electrocatalyst

Measurement evidence

Spectroscopy

Encapsulating metal organic framework into hollow mesoporous carbon sphere as efficient oxygen bifunctional electrocatalyst · Xiong W., Li H., You H. et al. · National Science Review · 2020 · 609-619

4 measurement groups · 6 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Inductively coupled plasma atomic emission spectrometry (ICP)

Co-HMCS · Powder

Co content in Co-HMCS

Context
Co-loaded HMCS control
Measurement source
611 · Results and discussion
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Co content in Co-HMCS1.16%Text
Exact Reported
611 · Results and discussion

Raman spectroscopy

HMCS · Powder

Raman spectrum of HMCS over 300-3500 cm^-1

Context
HMCS component
Measurement source
611 · Results and discussion · Fig. S2a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Raman ID/IG ratio of HMCSID/IG = 1.067Text
Exact Reported
611 · Results and discussion · Fig. S2a

X-ray photoelectron spectroscopy; Co 2p3/2 deconvolution

pure ZIF-67 · Powder

Coordination environment of pristine ZIF-67

Context
pristine MOF control
Measurement source
612 · Results and discussion · Fig. 2a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Co-Nx content in ZIF-6725.4%Text
Exact Reported
612 · Results and discussion · Fig. 2a

X-ray photoelectron spectroscopy; Co 2p3/2 and N 1s deconvolution

ZIF@HMCS-25% · Powder

Coordination environment of ZIF@HMCS-25%

Context
target composite
Measurement source
612-613 · Results and discussion · Fig. 2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Co-Nx peak downshift vs ZIF-670.33 eVText
Exact Reported
612 · Results and discussion · Fig. 2a
N 1s Co-N peak upshift~0.3 eVText
Approximate
613 · Results and discussion · Fig. 2b
Co-Nx content in ZIF@HMCS-25%Marked as a best value within this paper40.6%Text
Exact Reported
612 · Results and discussion · Fig. 2a