Electrochemistry Application — Bifunctional 3D-MOF-based nanoprobes for electrochemical sensing and nanozyme enhanced with peroxidase mimicking for colorimetric detection of acetaminophen

Measurement evidence

Electrochemistry Application

Bifunctional 3D-MOF-based nanoprobes for electrochemical sensing and nanozyme enhanced with peroxidase mimicking for colorimetric detection of acetaminophen · Nataraj N., Chen T.-W., Gan Z.-W. et al. · Materials Today Chemistry · 2022 · 100725

4 measurement groups · 4 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Electrochemical impedance spectroscopy

Bare GCE · Electrode

Bare GCE control measured in 5 mM ferri/ferrocyanide in 0.1 M KCl.

Geometry
Bare glassy carbon electrode
Context
Bare substrate control
Measurement source
4-5 · 3.2.1 Electrochemical resistance analysis · Fig. 3A
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Charge-transfer resistance of bare GCE733 OhmText
Exact Reported
4 · 3.2.1 Electrochemical resistance analysis · Fig. 3A

Electrochemical impedance spectroscopy

ZIF-67-A/GCE modified electrode · Electrode

Same EIS conditions as ZIF-67-C/GCE comparison: 5 mM ferri/ferrocyanide in 0.1 M KCl.

Geometry
ZIF-67-A modified GCE
Context
Composite electrode comparison
Measurement source
4-5 · 3.2.1 Electrochemical resistance analysis · Fig. 3A
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Charge-transfer resistance of ZIF-67-A/GCE164 OhmText
Exact Reported
4 · 3.2.1 Electrochemical resistance analysis · Fig. 3A

Electrochemical impedance spectroscopy

ZIF-67-C/GCE modified electrode · Electrode

5 mM [Fe(CN)6]3-/4- in 0.1 M KCl; frequency range 100 mHz to 100 kHz.

Geometry
ZIF-67-modified glassy carbon electrodes
Context
Composite electrode on GCE; compared with bare GCE and other ZIF-67 variants.
Measurement source
3-5 · 3.2.1 Electrochemical resistance analysis · Fig. 3A
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Charge-transfer resistance of ZIF-67-C/GCEMarked as a best value within this paper43 OhmText
Exact Reported
4 · 3.2.1 Electrochemical resistance analysis · Fig. 3A

Electrochemical impedance spectroscopy

ZIF-67-H/GCE modified electrode · Electrode

Same EIS conditions as ZIF-67-C/GCE comparison: 5 mM ferri/ferrocyanide in 0.1 M KCl.

Geometry
ZIF-67-H modified GCE
Context
Composite electrode comparison
Measurement source
4-5 · 3.2.1 Electrochemical resistance analysis · Fig. 3A
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Charge-transfer resistance of ZIF-67-H/GCE230 OhmText
Exact Reported
4 · 3.2.1 Electrochemical resistance analysis · Fig. 3A