Two-probe d.c. current-voltage conductivity on pressed pellets
pressed A2-TM-PTtSA pellets · Pellet
Variable-temperature conductivity in a climatic chamber; powder pressed at 384 MPa between carbon-coated aluminium foils and encapsulated in Swagelok cells under Ar.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Conductivity increase versus A4-PTtSA controls | A2-TM-PTtSA coordination polymers display two orders magnitude conductivity increase versus A4-PTtSA | — | — | Caption Rounded Reported | p016 / SI p.16 · Figure S7 caption · Figure S7 |
| Li2-Co-PTtSA log conductivity near room temperatureMarked as a best value within this paper | log10(sigma/S cm^-1) approximately -7.1 near 1000/T = 3.35 K^-1 | — | visual estimate +/-0.2 log unit | Figure Axis Approximate | p004 / article p.3926 · Figure 2 · Figure 2A |
| Li2-Fe-PTtSA log conductivity near room temperature | log10(sigma/S cm^-1) approximately -7.2 near 1000/T = 3.35 K^-1 | — | visual estimate +/-0.2 log unit | Figure Axis Approximate | p004 / article p.3926 · Figure 2 · Figure 2A |
| Room-temperature conductivity range for A2-TM-PTtSA | 10^-7 to 10^-6 S cm^-1 | — | — | Text Range | p004 / article p.3926 · Results and discussion · Figure 2A |