Diffraction Structure — Bimetal MOF nanosheets as efficient anode materials for lithium-ion batteries

Measurement evidence

Diffraction Structure

Bimetal MOF nanosheets as efficient anode materials for lithium-ion batteries · Liu X., Du J., Wu Y. et al. · Ionics · 2025 · 10097-10109

3 measurement groups · 5 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Post-cycling FTIR, PXRD, SEM, and TEM

Co1/2Fe1/2-MOF LIB anode electrode · Electrode

Co1/2Fe1/2-MOF electrode inspected in discharged, charged, pristine, and cycled states.

Geometry
cycled MOF/carbon/binder electrode
Context
cycled electrode
Measurement source
p010-p011 / article pp.10106-10107 · Results and discussion · Fig. 9
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Co1/2Fe1/2-MOF becomes amorphous after cyclingNo visible diffraction peaks after cycling; lost long-range organization and became amorphousText
Qualitative
p010-p011 / article pp.10106-10107 · Results and discussion · Fig. 9b
Co1/2Fe1/2-MOF morphology after cyclingMarked as a best value within this paperNo pulverization or fractures after cyclesText
Qualitative
p011 / article p.10107 · Results and discussion · Fig. 9c-d

Supplemental XRD, SEM, and TEM-SAED on dried/cycled Co1/2Fe1/2-MOF electrode materials

Co1/2Fe1/2-MOF LIB anode electrode · Electrode

Rendered SI shows XRD of dried Co1/2Fe1/2-MOF electrode material, SEM of dried electrode material, TEM-SAED of Co1/2Fe1/2-MOF, and XRD/SEM after 10 cycles.

Geometry
electrode material
Context
dried and cycled Co1/2Fe1/2-MOF electrode
Measurement source
p001-p003 · Supplementary Information · Fig. S1-S5
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Co1/2Fe1/2-MOF XRD after 10 cyclesXRD of Co1/2Fe1/2-MOF after 10 cycles shown in Fig. S5; broad/amorphous pattern in rendered SIVisual Estimate
Qualitative
p003 · Supplementary Information · Fig. S5
TEM-SAED purity indication for Co1/2Fe1/2-MOFTEM-SAED showed no obvious lattice fringes belonging to iron-rich or cobalt-rich secondary phasesText
Qualitative
p004 / article p.10100 · Results and discussion · Fig. S3

Powder X-ray diffraction (PXRD/XRD), Bruker D8 Advance, Cu-Ka radiation

CoxFe1-x-MOF powder/nanosheet series · Nanosheet

Patterns collected for CoxFe1-x-MOF powders; Fig. S1 reportedly includes dried Co1/2Fe1/2-MOF electrode material.

Context
pristine powder series
Measurement source
p003 / article p.10099 · Results and discussion · Fig. 1a; Fig. S1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
XRD structural framework retained across CoxFe1-x-MOF seriesCoxFe1-x-MOFs retain a consistent structural frameworkText
Qualitative
p003 / article p.10099 · Results and discussion · Fig. 1a