Powder XRD ageing stability comparison
as-synthesised CPO-27-Ni powder/crystals · Powder
PXRD of as-synthesised CPO-27-Ni and CPO-27-Ni after rigorous use/exposure for 2 years in ambient atmosphere.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| CPO-27-Ni ageing time before PXRD check | 2 years | — | — | Text Exact Reported | SI p.S2-S3 · Powder x-ray diffraction pattern of CPO-27-Ni · Figure S2 |
| ambient ageing relative humidity for CPO-27-Ni PXRD check | 45% RH | — | — | Text Exact Reported | SI p.S2-S3 · Powder x-ray diffraction pattern of CPO-27-Ni · Figure S2 |
| ambient ageing temperature for CPO-27-Ni PXRD check | 25 deg C | 298.15 K | — | Text Exact Reported | SI p.S2-S3 · Powder x-ray diffraction pattern of CPO-27-Ni · Figure S2 |
| CPO-27-Ni PXRD stability after ageingMarked as a best value within this paper | crystallinity retained without degradation | — | — | Text Qualitative | SI p.S2-S3 · Powder x-ray diffraction pattern of CPO-27-Ni · Figure S2 |