Electrochemistry Application — Regulating Crystallization and Lead Leakage of Perovskite Solar Cell Via Novel Polyoxometalate-Based Metal–Organic Framework

Measurement evidence

Electrochemistry Application

Regulating Crystallization and Lead Leakage of Perovskite Solar Cell Via Novel Polyoxometalate-Based Metal–Organic Framework · Dong Y., Zhang J., Wang W. et al. · Small · 2023 · 2301824

7 measurement groups · 82 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

IPCE/EQE raw-data spreadsheet

POMOF-functionalised n-i-p PSC · Electrode

Text-exported wavelength vs EQE (%) points for control and POMOF devices from 299.994 to 900.002 nm.

Geometry
FTO/ETL/perovskite/HTL/Au PSCs
Context
POMOF-composite device vs control
Measurement source
Sheet1 · IPCE/EQE raw data
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
peak EQE in raw IPCE spreadsheet, control83.955% at 639.987 nmTable
Exact Reported
Sheet1 · IPCE/EQE raw data
peak EQE in raw IPCE spreadsheet, POMOF86.65% at 544.986 nmTable
Exact Reported
Sheet1 · IPCE/EQE raw data

J-V raw-data spreadsheet

POMOF-functionalised n-i-p PSC · Electrode

Text-exported voltage/current-density curves for POMOF and control devices.

Atmosphere
air
Geometry
FTO/ETL/perovskite/HTL/Au PSCs
Context
POMOF-composite device vs control
Measurement source
Sheet1 · J-V raw data
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
raw J-V current density near 0 V, control24.82 mA cm-2 at 8.222e-05 VTable
Exact Reported
Sheet1 · J-V raw data
raw J-V current density near 0 V, POMOF25.2 mA cm-2 at 3.75e-05 VTable
Exact Reported
Sheet1 · J-V raw data
raw J-V zero-current voltage, control1.1362 V by linear interpolationCalculated From Reported
Approximate
Sheet1 · J-V raw data
raw J-V zero-current voltage, POMOF1.1982 V by linear interpolationCalculated From Reported
Approximate
Sheet1 · J-V raw data

Pb(II) sorption kinetics and isotherms by ICP-OES

POMOF Pb(II) sorbent · Powder

40 mg POMOF in 100 mL 10 ppm PbI2 for kinetics; 5 mg POMOF in 5 mL Pb(II) acetate solutions (10-1000 mg L-1) for 18 h isotherms.

Atmosphere
room temperature
Geometry
batch sorption
Context
pristine POMOF sorbent
Measurement source
p005-p006,p023 · Sorption kinetic; Sorption isotherms; Tables S7-S8 · Figure S24; Tables S7-S8
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
maximum Pb adsorption capacity rounded in main text714.7 mg g-1Text
Rounded Reported
p009 · 2.6 Mechanism Analysis · Figure S24c; Tables S7-S8
Freundlich KF232.75SI Table
Exact Reported
p023 · Table S7 · Table S7
Freundlich n4.01SI Table
Exact Reported
p023 · Table S7 · Table S7
Freundlich R20.79SI Table
Exact Reported
p023 · Table S7 · Table S7
Langmuir KL0.91SI Table
Exact Reported
p023 · Table S7 · Table S7
Langmuir maximum Pb adsorption capacity qm714.68 mg g-1SI Table
Exact Reported
p023 · Table S7 · Table S7
Langmuir R20.88SI Table
Exact Reported
p023 · Table S7 · Table S7
pseudo-first-order k10.64 min-1SI Table
Exact Reported
p023 · Table S8 · Table S8
pseudo-first-order qe,cal23.81 mg g-1SI Table
Exact Reported
p023 · Table S8 · Table S8
pseudo-first-order R20.98SI Table
Exact Reported
p023 · Table S8 · Table S8
pseudo-second-order k20.11 g mg-1 min-1SI Table
Exact Reported
p023 · Table S8 · Table S8
pseudo-second-order qe,cal10.08 mg g-1SI Table
Exact Reported
p023 · Table S8 · Table S8
pseudo-second-order R20.99SI Table
Exact Reported
p023 · Table S8 · Table S8

TOF-SIMS and ICP-OES Pb leakage assay

POMOF-functionalised n-i-p PSC · Electrode

Accelerated degradation under 85 degC/85% RH; contaminated water after immersing control and POMOF-functionalised PSCs analysed by ICP-OES; Figure 6f bar plot read visually.

Atmosphere
85 degC/85% RH for degradation; water soaking for ICP-OES
Geometry
PSC stack with Au electrode
Context
POMOF-composite device vs control
Measurement source
p008-p009 · 2.6 Mechanism Analysis of Lead Leakage Prevented by POMOF · Figure 6
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Pb concentration leaked, control PSC, 15 sabout 0.4 ppmVisual Estimate
Approximate
p008 · 2.6 Mechanism Analysis · Figure 6f
Pb concentration leaked, control PSC, 1800 sabout 7.8 ppmVisual Estimate
Approximate
p008 · 2.6 Mechanism Analysis · Figure 6f
Pb concentration leaked, control PSC, 3600 sabout 11.6 ppmVisual Estimate
Approximate
p008 · 2.6 Mechanism Analysis · Figure 6f
Pb concentration leaked, control PSC, 900 sabout 7.1 ppmVisual Estimate
Approximate
p008 · 2.6 Mechanism Analysis · Figure 6f
Pb concentration leaked, POMOF PSC, 1800 sabout 2.5 ppmVisual Estimate
Approximate
p008 · 2.6 Mechanism Analysis · Figure 6f
Pb concentration leaked, POMOF PSC, 3600 sabout 3.6 ppmVisual Estimate
Approximate
p008 · 2.6 Mechanism Analysis · Figure 6f
Pb concentration leaked, POMOF PSC, 900 sabout 2.3 ppmVisual Estimate
Approximate
p008 · 2.6 Mechanism Analysis · Figure 6f
TOF-SIMS Pb migration, aged control PSCPb2+ signal shifted toward Au electrode layer through HTL after degradationText
Qualitative
p009 · 2.6 Mechanism Analysis · Figure 6a,c
TOF-SIMS Pb migration, aged POMOF PSCalmost no Pb2+ ion signal appeared on Au electrode layerText
Qualitative
p009 · 2.6 Mechanism Analysis · Figure 6b,d

J-V photovoltaic characterisation

POMOF-functionalised n-i-p PSC · Electrode

AM 1.5G illumination in air; active area 0.06 cm2; reverse/forward scans.

Atmosphere
air
Geometry
FTO/ETL/perovskite/HTL/Au
Context
POMOF-composite device vs control
Measurement source
p007 · 2.5 Photovoltaic Performance of PSCs · Figure 5d; Tables S3,S6
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
hysteresis index, Control0.131SI Table
Exact Reported
p023 · Table S6 · Table S6
hysteresis index, Control0.131SI Table
Exact Reported
p023 · Table S6 · Table S6
hysteresis index, POMOF0.052SI Table
Exact Reported
p023 · Table S6 · Table S6
hysteresis index, POMOF0.052SI Table
Exact Reported
p023 · Table S6 · Table S6
FF, Control forward scan0.72SI Table
Exact Reported
p023 · Table S6 · Table S6
FF, Control reverse scan0.77SI Table
Exact Reported
p023 · Table S6 · Table S6
FF, POMOF PSC 0.5 mg mL-10.78SI Table
Exact Reported
p021 · Table S3 · Table S3
FF, POMOF PSC 1.0 mg mL-10.78SI Table
Exact Reported
p021 · Table S3 · Table S3
FF, POMOF PSC 1.5 mg mL-10.78SI Table
Exact Reported
p021 · Table S3 · Table S3
FF, POMOF PSC 2.0 mg mL-10.76SI Table
Exact Reported
p021 · Table S3 · Table S3
FF, POMOF PSC 3.0 mg mL-10.75SI Table
Exact Reported
p021 · Table S3 · Table S3
FF, POMOF forward scan0.76SI Table
Exact Reported
p023 · Table S6 · Table S6
FF, POMOF reverse scan0.78SI Table
Exact Reported
p023 · Table S6 · Table S6
Jsc, Control forward scan23.66SI Table
Exact Reported
p023 · Table S6 · Table S6
Jsc, Control reverse scan24.78SI Table
Exact Reported
p023 · Table S6 · Table S6
Jsc, POMOF PSC 0.5 mg mL-125.02SI Table
Exact Reported
p021 · Table S3 · Table S3
Jsc, POMOF PSC 1.0 mg mL-125.04SI Table
Exact Reported
p021 · Table S3 · Table S3
Jsc, POMOF PSC 1.5 mg mL-125.03SI Table
Exact Reported
p021 · Table S3 · Table S3
Jsc, POMOF PSC 2.0 mg mL-124.95SI Table
Exact Reported
p021 · Table S3 · Table S3
Jsc, POMOF PSC 3.0 mg mL-124.23SI Table
Exact Reported
p021 · Table S3 · Table S3
Jsc, POMOF forward scan24.7SI Table
Exact Reported
p023 · Table S6 · Table S6
Jsc, POMOF reverse scan25.03SI Table
Exact Reported
p023 · Table S6 · Table S6
PCE, Control forward scan19.13SI Table
Exact Reported
p023 · Table S6 · Table S6
PCE, Control reverse scan21.64SI Table
Exact Reported
p023 · Table S6 · Table S6
PCE, POMOF PSC 0.5 mg mL-122.67SI Table
Exact Reported
p021 · Table S3 · Table S3
PCE, POMOF PSC 1.0 mg mL-122.86SI Table
Exact Reported
p021 · Table S3 · Table S3
PCE, POMOF PSC 1.5 mg mL-1Marked as a best value within this paper23.3SI Table
Exact Reported
p021 · Table S3 · Table S3
PCE, POMOF PSC 2.0 mg mL-121.85SI Table
Exact Reported
p021 · Table S3 · Table S3
PCE, POMOF PSC 3.0 mg mL-120.7SI Table
Exact Reported
p021 · Table S3 · Table S3
PCE, POMOF forward scan22.09SI Table
Exact Reported
p023 · Table S6 · Table S6
PCE, POMOF reverse scanMarked as a best value within this paper23.3SI Table
Exact Reported
p023 · Table S6 · Table S6
Voc, Control forward scan1.127SI Table
Exact Reported
p023 · Table S6 · Table S6
Voc, Control reverse scan1.137SI Table
Exact Reported
p023 · Table S6 · Table S6
Voc, POMOF PSC 0.5 mg mL-11.151SI Table
Exact Reported
p021 · Table S3 · Table S3
Voc, POMOF PSC 1.0 mg mL-11.161SI Table
Exact Reported
p021 · Table S3 · Table S3
Voc, POMOF PSC 1.5 mg mL-11.194SI Table
Exact Reported
p021 · Table S3 · Table S3
Voc, POMOF PSC 2.0 mg mL-11.143SI Table
Exact Reported
p021 · Table S3 · Table S3
Voc, POMOF PSC 3.0 mg mL-11.136SI Table
Exact Reported
p021 · Table S3 · Table S3
Voc, POMOF forward scan1.181SI Table
Exact Reported
p023 · Table S6 · Table S6
Voc, POMOF reverse scan1.194SI Table
Exact Reported
p023 · Table S6 · Table S6

PCE statistics, IPCE, dark J-V and EIS

POMOF-functionalised n-i-p PSC · Electrode

Statistics for 50 PSCs; IPCE integrated Jsc; dark J-V and EIS used to assess recombination.

Atmosphere
air
Geometry
FTO/ETL/perovskite/HTL/Au
Context
POMOF-composite device vs control
Measurement source
p007-p008 · 2.5 Photovoltaic Performance of PSCs · Figure 5e; Figures S17-S19
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
average PCE, control PSCs20.97%Text
Exact Reported
p007 · 2.5 Photovoltaic Performance of PSCs · Figure 5e; Figure S17
average PCE, POMOF PSCs22.54%Text
Exact Reported
p007 · 2.5 Photovoltaic Performance of PSCs · Figure 5e; Figure S17
average Voc, control PSCs1.13 VText
Exact Reported
p007 · 2.5 Photovoltaic Performance of PSCs · Figure S17
average Voc, POMOF PSCs1.50 VText
Uncertain
p007 · 2.5 Photovoltaic Performance of PSCs · Figure S17
dark J-V leakage/recombinationPOMOF PSCs exhibit smaller dark current density than controlText
Qualitative
p007 · 2.5 Photovoltaic Performance of PSCs · Figure S18b
EIS recombination behaviourEIS supports reduced charge recombination in POMOF PSCsText
Qualitative
p008 · 2.5 Photovoltaic Performance of PSCs · Figure S19
integrated Jsc from IPCE, control23.2 mA cm-2Text
Exact Reported
p007 · 2.5 Photovoltaic Performance of PSCs · Figure S18a
integrated Jsc from IPCE, POMOF24.0 mA cm-2Text
Exact Reported
p007 · 2.5 Photovoltaic Performance of PSCs · Figure S18a

Maximum power tracking and stability tests

POMOF-functionalised n-i-p PSC · Electrode

Stabilised power output for 300 s under AM 1.5G; ageing at 30% RH/25 degC for 1600 h; thermal annealing at 85 degC in nitrogen for 1000 h.

Atmosphere
air/nitrogen
Geometry
unencapsulated PSCs
Context
POMOF-composite device vs control
Measurement source
p008 · 2.5 Photovoltaic Performance of PSCs · Figure 5f-h; Figures S20-S21
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
PCE retention after 1600 h at 30% RH/25 degC, controlloss of about 60% (retention about 40%)Calculated From Reported
Approximate
p008 · 2.5 Photovoltaic Performance of PSCs · Figure 5g; Figure S20
PCE retention after 1600 h at 30% RH/25 degC, POMOFnearly 90%Text
Approximate
p008 · 2.5 Photovoltaic Performance of PSCs · Figure 5g; Figure S20
stabilised PCE after 300 s MPP, control20.80%Text
Exact Reported
p008 · 2.5 Photovoltaic Performance of PSCs · Figure 5f
stabilised PCE after 300 s MPP, POMOF22.75%Text
Exact Reported
p008 · 2.5 Photovoltaic Performance of PSCs · Figure 5f
PCE retention after 1000 h at 85 degC, controlabout 60%Text
Approximate
p008 · 2.5 Photovoltaic Performance of PSCs · Figure 5h; Figure S21
PCE retention after 1000 h at 85 degC, POMOF85%Text
Approximate
p008 · 2.5 Photovoltaic Performance of PSCs · Figure 5h; Figure S21