| LiClO4 / DMF film 1 apparent diffusion coefficient Dapp_e | 3.441e-09 cm2 s^-1 | — | — | SI Table Exact Reported | 6 · Chronoamperometry and Cottrell Analysis · Table S1 |
| LiClO4 / DMF film 1 film thickness df | 1.458 um | — | — | SI Table Exact Reported | 6 · Chronoamperometry and Cottrell Analysis · Table S1 |
| LiClO4 / DMF film 1 electroactive NDI surface concentration Gamma_e | 5.874e-08 mol cm^-2 | — | — | SI Table Exact Reported | 6 · Chronoamperometry and Cottrell Analysis · Table S1 |
| LiClO4 / DMF film 1 charge Q | -6.405 mC | — | — | SI Table Exact Reported | 6 · Chronoamperometry and Cottrell Analysis · Table S1 |
| LiClO4 / DMF film 1 surface area SA | 1.130 cm2 | — | — | SI Table Exact Reported | 6 · Chronoamperometry and Cottrell Analysis · Table S1 |
| LiClO4 / DMF film 1 Cottrell slope | 1.287 | — | — | SI Table Exact Reported | 6 · Chronoamperometry and Cottrell Analysis · Table S1 |
| LiClO4 / DMF film 2 apparent diffusion coefficient Dapp_e | 9.775e-10 cm2 s^-1 | — | — | SI Table Exact Reported | 6 · Chronoamperometry and Cottrell Analysis · Table S1 |
| LiClO4 / DMF film 2 film thickness df | 0.835 um | — | — | SI Table Exact Reported | 6 · Chronoamperometry and Cottrell Analysis · Table S1 |
| LiClO4 / DMF film 2 electroactive NDI surface concentration Gamma_e | 5.670e-08 mol cm^-2 | — | — | SI Table Exact Reported | 6 · Chronoamperometry and Cottrell Analysis · Table S1 |
| LiClO4 / DMF film 2 charge Q | -5.760 mC | — | — | SI Table Exact Reported | 6 · Chronoamperometry and Cottrell Analysis · Table S1 |
| LiClO4 / DMF film 2 surface area SA | 1.053 cm2 | — | — | SI Table Exact Reported | 6 · Chronoamperometry and Cottrell Analysis · Table S1 |
| LiClO4 / DMF film 2 Cottrell slope | 1.156 | — | — | SI Table Exact Reported | 6 · Chronoamperometry and Cottrell Analysis · Table S1 |
| LiClO4 / DMF film 3 apparent diffusion coefficient Dapp_e | 5.278e-09 cm2 s^-1 | — | — | SI Table Exact Reported | 6 · Chronoamperometry and Cottrell Analysis · Table S1 |
| LiClO4 / DMF film 3 film thickness df | 1.411 um | — | — | SI Table Exact Reported | 6 · Chronoamperometry and Cottrell Analysis · Table S1 |
| LiClO4 / DMF film 3 electroactive NDI surface concentration Gamma_e | 6.422e-08 mol cm^-2 | — | — | SI Table Exact Reported | 6 · Chronoamperometry and Cottrell Analysis · Table S1 |
| LiClO4 / DMF film 3 charge Q | -5.985 mC | — | — | SI Table Exact Reported | 6 · Chronoamperometry and Cottrell Analysis · Table S1 |
| LiClO4 / DMF film 3 surface area SA | 0.966 cm2 | — | — | SI Table Exact Reported | 6 · Chronoamperometry and Cottrell Analysis · Table S1 |
| LiClO4 / DMF film 3 Cottrell slope | 1.800 | — | — | SI Table Exact Reported | 6 · Chronoamperometry and Cottrell Analysis · Table S1 |
| LiClO4 / EtOH film 1 apparent diffusion coefficient Dapp_e | 1.599e-10 cm2 s^-1 | — | — | SI Table Exact Reported | 7 · Chronoamperometry and Cottrell Analysis · Table S2 |
| LiClO4 / EtOH film 1 film thickness df | 0.963 um | — | — | SI Table Exact Reported | 7 · Chronoamperometry and Cottrell Analysis · Table S2 |
| LiClO4 / EtOH film 1 electroactive NDI surface concentration Gamma_e | 6.315e-08 mol cm^-2 | — | — | SI Table Exact Reported | 7 · Chronoamperometry and Cottrell Analysis · Table S2 |
| LiClO4 / EtOH film 1 charge Q | 5.795 mC | — | — | SI Table Exact Reported | 7 · Chronoamperometry and Cottrell Analysis · Table S2 |
| LiClO4 / EtOH film 1 surface area SA | 0.951 cm2 | — | — | SI Table Exact Reported | 7 · Chronoamperometry and Cottrell Analysis · Table S2 |
| LiClO4 / EtOH film 1 Cottrell slope | 0.451 | — | — | SI Table Exact Reported | 7 · Chronoamperometry and Cottrell Analysis · Table S2 |
| LiClO4 / EtOH film 2 apparent diffusion coefficient Dapp_e | 1.335e-10 cm2 s^-1 | — | — | SI Table Exact Reported | 7 · Chronoamperometry and Cottrell Analysis · Table S2 |
| LiClO4 / EtOH film 2 film thickness df | 1.092 um | — | — | SI Table Exact Reported | 7 · Chronoamperometry and Cottrell Analysis · Table S2 |
| LiClO4 / EtOH film 2 electroactive NDI surface concentration Gamma_e | 6.648e-08 mol cm^-2 | — | — | SI Table Exact Reported | 7 · Chronoamperometry and Cottrell Analysis · Table S2 |
| LiClO4 / EtOH film 2 charge Q | 7.530 mC | — | — | SI Table Exact Reported | 7 · Chronoamperometry and Cottrell Analysis · Table S2 |
| LiClO4 / EtOH film 2 surface area SA | 1.174 cm2 | — | — | SI Table Exact Reported | 7 · Chronoamperometry and Cottrell Analysis · Table S2 |
| LiClO4 / EtOH film 2 Cottrell slope | 0.383 | — | — | SI Table Exact Reported | 7 · Chronoamperometry and Cottrell Analysis · Table S2 |
| LiClO4 / EtOH film 3 apparent diffusion coefficient Dapp_e | 4.144e-10 cm2 s^-1 | — | — | SI Table Exact Reported | 7 · Chronoamperometry and Cottrell Analysis · Table S2 |
| LiClO4 / EtOH film 3 film thickness df | 1.941 um | — | — | SI Table Exact Reported | 7 · Chronoamperometry and Cottrell Analysis · Table S2 |
| LiClO4 / EtOH film 3 electroactive NDI surface concentration Gamma_e | 4.895e-08 mol cm^-2 | — | — | SI Table Exact Reported | 7 · Chronoamperometry and Cottrell Analysis · Table S2 |
| LiClO4 / EtOH film 3 charge Q | 5.578 mC | — | — | SI Table Exact Reported | 7 · Chronoamperometry and Cottrell Analysis · Table S2 |
| LiClO4 / EtOH film 3 surface area SA | 1.181 cm2 | — | — | SI Table Exact Reported | 7 · Chronoamperometry and Cottrell Analysis · Table S2 |
| LiClO4 / EtOH film 3 Cottrell slope | 0.279 | — | — | SI Table Exact Reported | 7 · Chronoamperometry and Cottrell Analysis · Table S2 |
| LiClO4 / THF film 1 apparent diffusion coefficient Dapp_e | 1.463e-11 cm2 s^-1 | — | — | SI Table Exact Reported | 8 · Chronoamperometry and Cottrell Analysis · Table S3 |
| LiClO4 / THF film 1 film thickness df | 0.705 um | — | — | SI Table Exact Reported | 8 · Chronoamperometry and Cottrell Analysis · Table S3 |
| LiClO4 / THF film 1 electroactive NDI surface concentration Gamma_e | 8.041e-08 mol cm^-2 | — | — | SI Table Exact Reported | 8 · Chronoamperometry and Cottrell Analysis · Table S3 |
| LiClO4 / THF film 1 charge Q | 8.100 mC | — | — | SI Table Exact Reported | 8 · Chronoamperometry and Cottrell Analysis · Table S3 |
| LiClO4 / THF film 1 surface area SA | 1.044 cm2 | — | — | SI Table Exact Reported | 8 · Chronoamperometry and Cottrell Analysis · Table S3 |
| LiClO4 / THF film 1 Cottrell slope | 0.238 | — | — | SI Table Exact Reported | 8 · Chronoamperometry and Cottrell Analysis · Table S3 |
| LiClO4 / THF film 2 apparent diffusion coefficient Dapp_e | 1.416e-11 cm2 s^-1 | — | — | SI Table Exact Reported | 8 · Chronoamperometry and Cottrell Analysis · Table S3 |
| LiClO4 / THF film 2 film thickness df | 0.879 um | — | — | SI Table Exact Reported | 8 · Chronoamperometry and Cottrell Analysis · Table S3 |
| LiClO4 / THF film 2 electroactive NDI surface concentration Gamma_e | 6.909e-08 mol cm^-2 | — | — | SI Table Exact Reported | 8 · Chronoamperometry and Cottrell Analysis · Table S3 |
| LiClO4 / THF film 2 charge Q | 6.519 mC | — | — | SI Table Exact Reported | 8 · Chronoamperometry and Cottrell Analysis · Table S3 |
| LiClO4 / THF film 2 surface area SA | 0.978 cm2 | — | — | SI Table Exact Reported | 8 · Chronoamperometry and Cottrell Analysis · Table S3 |
| LiClO4 / THF film 2 Cottrell slope | 0.161 | — | — | SI Table Exact Reported | 8 · Chronoamperometry and Cottrell Analysis · Table S3 |
| LiClO4 / THF film 3 apparent diffusion coefficient Dapp_e | 1.020e-11 cm2 s^-1 | — | — | SI Table Exact Reported | 8 · Chronoamperometry and Cottrell Analysis · Table S3 |
| LiClO4 / THF film 3 film thickness df | 0.643 um | — | — | SI Table Exact Reported | 8 · Chronoamperometry and Cottrell Analysis · Table S3 |
| LiClO4 / THF film 3 electroactive NDI surface concentration Gamma_e | 5.499e-08 mol cm^-2 | — | — | SI Table Exact Reported | 8 · Chronoamperometry and Cottrell Analysis · Table S3 |
| LiClO4 / THF film 3 charge Q | 4.929 mC | — | — | SI Table Exact Reported | 8 · Chronoamperometry and Cottrell Analysis · Table S3 |
| LiClO4 / THF film 3 surface area SA | 0.929 cm2 | — | — | SI Table Exact Reported | 8 · Chronoamperometry and Cottrell Analysis · Table S3 |
| LiClO4 / THF film 3 Cottrell slope | 0.149 | — | — | SI Table Exact Reported | 8 · Chronoamperometry and Cottrell Analysis · Table S3 |
| KPF6 / DMF film 1 apparent diffusion coefficient Dapp_e | 1.022e-09 cm2 s^-1 | — | — | SI Table Exact Reported | 9 · Chronoamperometry and Cottrell Analysis · Table S4 |
| KPF6 / DMF film 1 film thickness df | 0.786 um | — | — | SI Table Exact Reported | 9 · Chronoamperometry and Cottrell Analysis · Table S4 |
| KPF6 / DMF film 1 electroactive NDI surface concentration Gamma_e | 8.673e-08 mol cm^-2 | — | — | SI Table Exact Reported | 9 · Chronoamperometry and Cottrell Analysis · Table S4 |
| KPF6 / DMF film 1 charge Q | 8.493 mC | — | — | SI Table Exact Reported | 9 · Chronoamperometry and Cottrell Analysis · Table S4 |
| KPF6 / DMF film 1 surface area SA | 1.015 cm2 | — | — | SI Table Exact Reported | 9 · Chronoamperometry and Cottrell Analysis · Table S4 |
| KPF6 / DMF film 1 Cottrell slope | 1.920 | — | — | SI Table Exact Reported | 9 · Chronoamperometry and Cottrell Analysis · Table S4 |
| KPF6 / DMF film 2 apparent diffusion coefficient Dapp_e | 8.815e-10 cm2 s^-1 | — | — | SI Table Exact Reported | 9 · Chronoamperometry and Cottrell Analysis · Table S4 |
| KPF6 / DMF film 2 film thickness df | 0.849 um | — | — | SI Table Exact Reported | 9 · Chronoamperometry and Cottrell Analysis · Table S4 |
| KPF6 / DMF film 2 electroactive NDI surface concentration Gamma_e | 9.343e-08 mol cm^-2 | — | — | SI Table Exact Reported | 9 · Chronoamperometry and Cottrell Analysis · Table S4 |
| KPF6 / DMF film 2 charge Q | 7.798 mC | — | — | SI Table Exact Reported | 9 · Chronoamperometry and Cottrell Analysis · Table S4 |
| KPF6 / DMF film 2 surface area SA | 0.865 cm2 | — | — | SI Table Exact Reported | 9 · Chronoamperometry and Cottrell Analysis · Table S4 |
| KPF6 / DMF film 2 Cottrell slope | 1.779 | — | — | SI Table Exact Reported | 9 · Chronoamperometry and Cottrell Analysis · Table S4 |
| KPF6 / DMF film 3 apparent diffusion coefficient Dapp_e | 1.465e-09 cm2 s^-1 | — | — | SI Table Exact Reported | 9 · Chronoamperometry and Cottrell Analysis · Table S4 |
| KPF6 / DMF film 3 film thickness df | 0.683 um | — | — | SI Table Exact Reported | 9 · Chronoamperometry and Cottrell Analysis · Table S4 |
| KPF6 / DMF film 3 electroactive NDI surface concentration Gamma_e | 5.754e-08 mol cm^-2 | — | — | SI Table Exact Reported | 9 · Chronoamperometry and Cottrell Analysis · Table S4 |
| KPF6 / DMF film 3 charge Q | 4.958 mC | — | — | SI Table Exact Reported | 9 · Chronoamperometry and Cottrell Analysis · Table S4 |
| KPF6 / DMF film 3 surface area SA | 0.893 cm2 | — | — | SI Table Exact Reported | 9 · Chronoamperometry and Cottrell Analysis · Table S4 |
| KPF6 / DMF film 3 Cottrell slope | 1.756 | — | — | SI Table Exact Reported | 9 · Chronoamperometry and Cottrell Analysis · Table S4 |
| TBAPF6 / DMF film 1 apparent diffusion coefficient Dapp_e | 1.219e-09 cm2 s^-1 | — | — | SI Table Exact Reported | 10 · Chronoamperometry and Cottrell Analysis · Table S5 |
| TBAPF6 / DMF film 1 film thickness df | 1.002 um | — | — | SI Table Exact Reported | 10 · Chronoamperometry and Cottrell Analysis · Table S5 |
| TBAPF6 / DMF film 1 electroactive NDI surface concentration Gamma_e | 3.665e-08 mol cm^-2 | — | — | SI Table Exact Reported | 10 · Chronoamperometry and Cottrell Analysis · Table S5 |
| TBAPF6 / DMF film 1 charge Q | 3.561 mC | — | — | SI Table Exact Reported | 10 · Chronoamperometry and Cottrell Analysis · Table S5 |
| TBAPF6 / DMF film 1 surface area SA | 1.007 cm2 | — | — | SI Table Exact Reported | 10 · Chronoamperometry and Cottrell Analysis · Table S5 |
| TBAPF6 / DMF film 1 Cottrell slope | 0.695 | — | — | SI Table Exact Reported | 10 · Chronoamperometry and Cottrell Analysis · Table S5 |
| TBAPF6 / DMF film 2 apparent diffusion coefficient Dapp_e | 8.303e-10 cm2 s^-1 | — | — | SI Table Exact Reported | 10 · Chronoamperometry and Cottrell Analysis · Table S5 |
| TBAPF6 / DMF film 2 film thickness df | 1.322 um | — | — | SI Table Exact Reported | 10 · Chronoamperometry and Cottrell Analysis · Table S5 |
| TBAPF6 / DMF film 2 electroactive NDI surface concentration Gamma_e | 5.824e-08 mol cm^-2 | — | — | SI Table Exact Reported | 10 · Chronoamperometry and Cottrell Analysis · Table S5 |
| TBAPF6 / DMF film 2 charge Q | 5.339 mC | — | — | SI Table Exact Reported | 10 · Chronoamperometry and Cottrell Analysis · Table S5 |
| TBAPF6 / DMF film 2 surface area SA | 0.950 cm2 | — | — | SI Table Exact Reported | 10 · Chronoamperometry and Cottrell Analysis · Table S5 |
| TBAPF6 / DMF film 2 Cottrell slope | 0.691 | — | — | SI Table Exact Reported | 10 · Chronoamperometry and Cottrell Analysis · Table S5 |
| TBAPF6 / DMF film 3 apparent diffusion coefficient Dapp_e | 4.708e-11 cm2 s^-1 | — | — | SI Table Exact Reported | 10 · Chronoamperometry and Cottrell Analysis · Table S5 |
| TBAPF6 / DMF film 3 film thickness df | 0.605 um | — | — | SI Table Exact Reported | 10 · Chronoamperometry and Cottrell Analysis · Table S5 |
| TBAPF6 / DMF film 3 electroactive NDI surface concentration Gamma_e | 2.307e-08 mol cm^-2 | — | — | SI Table Exact Reported | 10 · Chronoamperometry and Cottrell Analysis · Table S5 |
| TBAPF6 / DMF film 3 charge Q | 1.761 mC | — | — | SI Table Exact Reported | 10 · Chronoamperometry and Cottrell Analysis · Table S5 |
| TBAPF6 / DMF film 3 surface area SA | 0.791 cm2 | — | — | SI Table Exact Reported | 10 · Chronoamperometry and Cottrell Analysis · Table S5 |
| TBAPF6 / DMF film 3 Cottrell slope | 0.142 | — | — | SI Table Exact Reported | 10 · Chronoamperometry and Cottrell Analysis · Table S5 |
| TBAPF6 / THF film 1 apparent diffusion coefficient Dapp_e | 3.723e-11 cm2 s^-1 | — | — | SI Table Exact Reported | 11 · Chronoamperometry and Cottrell Analysis · Table S6 |
| TBAPF6 / THF film 1 film thickness df | 1.242 um | — | — | SI Table Exact Reported | 11 · Chronoamperometry and Cottrell Analysis · Table S6 |
| TBAPF6 / THF film 1 electroactive NDI surface concentration Gamma_e | 7.207e-08 mol cm^-2 | — | — | SI Table Exact Reported | 11 · Chronoamperometry and Cottrell Analysis · Table S6 |
| TBAPF6 / THF film 1 charge Q | 6.954 mC | — | — | SI Table Exact Reported | 11 · Chronoamperometry and Cottrell Analysis · Table S6 |
| TBAPF6 / THF film 1 surface area SA | 1.000 cm2 | — | — | SI Table Exact Reported | 11 · Chronoamperometry and Cottrell Analysis · Table S6 |
| TBAPF6 / THF film 1 Cottrell slope | 0.193 | — | — | SI Table Exact Reported | 11 · Chronoamperometry and Cottrell Analysis · Table S6 |
| TBAPF6 / THF film 2 apparent diffusion coefficient Dapp_e | 1.674e-11 cm2 s^-1 | — | — | SI Table Exact Reported | 11 · Chronoamperometry and Cottrell Analysis · Table S6 |
| TBAPF6 / THF film 2 film thickness df | 0.889 um | — | — | SI Table Exact Reported | 11 · Chronoamperometry and Cottrell Analysis · Table S6 |
| TBAPF6 / THF film 2 electroactive NDI surface concentration Gamma_e | 2.348e-08 mol cm^-2 | — | — | SI Table Exact Reported | 11 · Chronoamperometry and Cottrell Analysis · Table S6 |
| TBAPF6 / THF film 2 charge Q | 2.520 mC | — | — | SI Table Exact Reported | 11 · Chronoamperometry and Cottrell Analysis · Table S6 |
| TBAPF6 / THF film 2 surface area SA | 1.112 cm2 | — | — | SI Table Exact Reported | 11 · Chronoamperometry and Cottrell Analysis · Table S6 |
| TBAPF6 / THF film 2 Cottrell slope | 0.059 | — | — | SI Table Exact Reported | 11 · Chronoamperometry and Cottrell Analysis · Table S6 |
| TBAPF6 / THF film 3 apparent diffusion coefficient Dapp_e | 2.992e-11 cm2 s^-1 | — | — | SI Table Exact Reported | 11 · Chronoamperometry and Cottrell Analysis · Table S6 |
| TBAPF6 / THF film 3 film thickness df | 1.042 um | — | — | SI Table Exact Reported | 11 · Chronoamperometry and Cottrell Analysis · Table S6 |
| TBAPF6 / THF film 3 electroactive NDI surface concentration Gamma_e | 2.313e-08 mol cm^-2 | — | — | SI Table Exact Reported | 11 · Chronoamperometry and Cottrell Analysis · Table S6 |
| TBAPF6 / THF film 3 charge Q | 2.114 mC | — | — | SI Table Exact Reported | 11 · Chronoamperometry and Cottrell Analysis · Table S6 |
| TBAPF6 / THF film 3 surface area SA | 0.947 cm2 | — | — | SI Table Exact Reported | 11 · Chronoamperometry and Cottrell Analysis · Table S6 |
| TBAPF6 / THF film 3 Cottrell slope | 0.066 | — | — | SI Table Exact Reported | 11 · Chronoamperometry and Cottrell Analysis · Table S6 |