Hg-drop tunnelling junction current-voltage measurement
F4-TCNQ-loaded HKUST-1 SURMOF, 5 spray cycles · Thin Film
F4-TCNQ-loaded SURMOF measured in Hg/HDT//SURMOF/CMMT/Au geometry; bias swept as for pristine samples; 5-10 positions averaged.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| F4-TCNQ-loaded current density at 0.5 V | approximately 1e-4 A/cm2 at +0.5 V from Figure 5a | — | visual estimate | Figure Axis Approximate | 7090 · Results and Discussion · Figure 5a |