Microscopy Morphology — Controllable proton-conducting pathways: Via situating polyoxometalates in targeting pores of a metal-organic framework

Measurement evidence

Microscopy Morphology

Controllable proton-conducting pathways: Via situating polyoxometalates in targeting pores of a metal-organic framework · Lai X., Liu Y., Yang G. et al. · Journal of Materials Chemistry A · 2017 · 9611-9617

1 measurement group · 16 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

EDX using HITACHI SU8010 SEM with TEAM EDS

TETA@3 · Powder

EDX used to determine the number of N atoms/proton-hopping sites per Cr(III) ion.

Geometry
SEM-EDX
Context
Polyamine loading quantification
Measurement source
main p.5 · Results and discussion · Table 2; Fig. S16-S17
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
1.2TETA@3 N atoms per Cr(III)2.38Table
Exact Reported
main p.5 · Results and discussion · Table 2
1.2TETA@3 polyamine/Cr ratio0.59Table
Exact Reported
main p.5 · Results and discussion · Table 2
DETA@3 N atoms per Cr(III)4.13Table
Exact Reported
main p.5 · Results and discussion · Table 2
DETA@3 polyamine/Cr ratio1.38Table
Exact Reported
main p.5 · Results and discussion · Table 2
DETA molecular size7.471 ATable
Exact Reported
main p.5 · Results and discussion · Table 2
EN@3 N atoms per Cr(III)2.88Table
Exact Reported
main p.5 · Results and discussion · Table 2
EN@3 polyamine/Cr ratio1.44Table
Exact Reported
main p.5 · Results and discussion · Table 2
EN molecular size3.821 ATable
Exact Reported
main p.5 · Results and discussion · Table 2
TEPA@3 N atoms per Cr(III)6.49Table
Exact Reported
main p.5 · Results and discussion · Table 2
TEPA@3 polyamine/Cr ratio1.30Table
Exact Reported
main p.5 · Results and discussion · Table 2
TEPA molecular size14.868 ATable
Exact Reported
main p.5 · Results and discussion · Table 2
TETA@MIL-101 N atoms per Cr(III)4.64Table
Exact Reported
main p.5 · Results and discussion · Table 2
TETA@MIL-101 polyamine/Cr ratio1.16Table
Exact Reported
main p.5 · Results and discussion · Table 2
TETA@3 N atoms per Cr(III)5.41Table
Exact Reported
main p.5 · Results and discussion · Table 2
TETA@3 polyamine/Cr ratio1.35Table
Exact Reported
main p.5 · Results and discussion · Table 2
TETA molecular size11.209 ATable
Exact Reported
main p.5 · Results and discussion · Table 2