Spectroscopy — Structure-directing effect of terephthalate in bridging Zn(ii)- and Cd(ii)-based coordination polymers towards application in the detection of trace quantities of Pd2+ in aqueous media and their electrical conductivities

Measurement evidence

Spectroscopy

Structure-directing effect of terephthalate in bridging Zn(ii)- and Cd(ii)-based coordination polymers towards application in the detection of trace quantities of Pd2+ in aqueous media and their electrical conductivities · Saha K., Dutta B., Das P. et al. · Dalton Transactions · 2025 · 3346-3361

6 measurement groups · 20 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Time-resolved fluorescence lifetime

[CP1 + Pd2+] · Powder

Lifetime recorded before and after Pd2+ addition; decay profile mono-exponential.

Geometry
suspension
Context
CP1 before/after Pd2+
Measurement source
5 · Sensing studies of CP1 and CP2 · Fig. S21
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
fluorescence lifetime after Pd2+2.34 nsText
Exact Reported
5 · Sensing studies · Fig. S21
fluorescence lifetime before Pd2+1.90 nsText
Exact Reported
5 · Sensing studies · Fig. S21

UV-visible absorption and photoluminescence

CP1 as-synthesised block-shaped yellow crystals · Single Crystal

DMF suspension; excitation at 285 nm for CP1; emission and absorption spectra used for sensing and band assignments.

Context
pristine CP1
Measurement source
4 · Sensing studies of CP1 and CP2 · Fig. S10/Fig. 3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
absorption maximum285 nmText
Exact Reported
4 · Sensing studies · Fig. S10
absorption shoulder320 nmText
Exact Reported
4 · Sensing studies · Fig. S10
emission transition380 nmText
Exact Reported
4 · Sensing studies · Fig. 3

XPS and EDS after Pd2+ exposure

[CP1 + Pd2+] · Powder

XPS survey/high-resolution C 1s/N 1s/Pd 3d and EDS atomic percent for CP1 and [CP1+Pd2+].

Geometry
powder/surface
Context
CP1 plus Pd2+ guest interaction
Measurement source
7-8 · XPS discussion · Fig. 6/Table S9
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CP1 C(sp3) binding-energy shift after Pd2+283.83 to 284.32 eV; shift 0.49 eVText
Exact Reported
7 · XPS discussion · Fig. 6
CP1 imine-N N 1s binding-energy shift after Pd2+399.0 to 399.26 eV, DeltaE ~0.26 eVText
Approximate
7 · XPS discussion · Fig. 6
Pd 3d3/2 binding energy in [CP1+Pd2+]343.14 eVText
Exact Reported
9 · XPS discussion · Fig. 6
Pd 3d5/2 binding energy in [CP1+Pd2+]337.80 eVText
Exact Reported
9 · XPS discussion · Fig. 6
Pd atomic percent after Pd2+ exposure0.50 atomic % Pd in [CP1+Pd2+]SI Table
Exact Reported
29 · EDS atomic percent · Table S9

Time-resolved fluorescence lifetime

[CP2 + Pd2+] · Powder

Lifetime recorded before and after Pd2+ addition; decay profile mono-exponential.

Geometry
suspension
Context
CP2 before/after Pd2+
Measurement source
5 · Sensing studies of CP1 and CP2 · Fig. S22
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
fluorescence lifetime after Pd2+2.09 nsText
Exact Reported
5 · Sensing studies · Fig. S22
fluorescence lifetime before Pd2+1.80 nsText
Exact Reported
5 · Sensing studies · Fig. S22

UV-visible absorption and photoluminescence

CP2 as-synthesised yellow needle-like crystals · Single Crystal

DMF suspension; excitation at 278 nm for CP2; emission and absorption spectra used for sensing and band assignments.

Context
pristine CP2
Measurement source
4 · Sensing studies of CP1 and CP2 · Fig. S10/Fig. 4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
absorption maximum278 nmText
Exact Reported
4 · Sensing studies · Fig. S10
absorption shoulder315 nmText
Exact Reported
4 · Sensing studies · Fig. S10
emission transition384 nmText
Exact Reported
4 · Sensing studies · Fig. 4

XPS and EDS after Pd2+ exposure

[CP2 + Pd2+] · Powder

XPS survey/high-resolution C 1s/N 1s/Pd 3d and EDS atomic percent for CP2 and [CP2+Pd2+].

Geometry
powder/surface
Context
CP2 plus Pd2+ guest interaction
Measurement source
8-9 · XPS discussion · Fig. 7/Table 1/Table S9
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CP2 imine C 1s binding-energy shift after Pd2+285.98 to 286.46 eV; shift 0.48 eVTable
Exact Reported
9 · XPS discussion · Table 1
CP2 imine N 1s binding-energy shift after Pd2+398.95 to 399.39 eV; shift 0.44 eVTable
Exact Reported
9 · XPS discussion · Table 1
Pd 3d3/2 binding energy in [CP2+Pd2+]342.86 eVText
Exact Reported
9 · XPS discussion · Fig. 7
Pd 3d5/2 binding energy in [CP2+Pd2+]337.65 eVText
Exact Reported
9 · XPS discussion · Fig. 7
Pd atomic percent after Pd2+ exposure0.55 atomic % Pd in [CP2+Pd2+]SI Table
Exact Reported
29 · EDS atomic percent · Table S9