PXRD / XRD
1-Ag@ZIF-8 · Powder
PXRD of Ag/ZIF-8 nanocomposite used to assess ZIF-8 and Ag phases.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|
Measurement evidence
Fabrication of high-performance supercapacitor of surface-engineered ZIF-8 for energy storage applications · Karim M.R., Choi C.-H., Mohammad A. et al. · Journal of Energy Storage · 2024 · 112199
Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.
1-Ag@ZIF-8 · Powder
PXRD of Ag/ZIF-8 nanocomposite used to assess ZIF-8 and Ag phases.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|
2-Ag@ZIF-8 · Powder
PXRD of higher-Ag Ag/ZIF-8 nanocomposite used to assess ZIF-8 and Ag phases.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| 2-Ag@ZIF-8 higher Ag ratio from peak intensity | ZIF-8 peak intensity of 2-Ag@ZIF-8 lower than 1-Ag@ZIF-8, indicating higher Ag ratio | — | — | Text Qualitative | 3 · 3.1. Structural and morphological characterization · Fig. 2a |
| Metallic Ag0 phase assignment | Ag/ZIF-8 diffraction features attributed to metallic Ag0, JCPDS no. 04-0783 | — | — | Text Qualitative | 3 · 3.1. Structural and morphological characterization · Fig. 2a |
ZIF-8 · Powder
Powder X-ray diffraction pattern compared with reported ZIF-8 patterns.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| ZIF-8 indexed diffraction peaks | 7.4, 10.4, 12.7 and 18.0 deg corresponding to (011), (002), (112) and (222) ZIF-8 lattice planes | — | — | Text Rounded Reported | 3 · 3.1. Structural and morphological characterization · Fig. 2a |