Cyclic voltammetry of drop-cast polymer film
P1 poly[Kx(Ni-ett)] · Pellet
CH3CN, 0.1 M tetrabutylammonium hexafluorophosphate, N2, 50 mV s^-1, Fc/Fc+ referenced to 0.00 V.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| irreversible_ni_reduction_vs_vacuum | -3.5 eV | — | — | Text Approximate | 8 · Cyclic voltammetry · Fig. 5 |
| irreversible_ni_reduction_vs_fc | -1.59 V | — | — | Text Rounded Reported | 8 · Cyclic voltammetry · Fig. 5 |
| partial_ni_reduction_energy_max | -4.7 eV | — | — | Text Range | 8 · Cyclic voltammetry · Fig. 5 |
| partial_ni_reduction_energy_min | -5.0 eV | — | — | Text Range | 8 · Cyclic voltammetry · Fig. 5 |