Diffraction Structure — New coordination polymers of 1,4-bis(2′-hydroxyphenylazomethine) phenylene

Measurement evidence

Diffraction Structure

New coordination polymers of 1,4-bis(2′-hydroxyphenylazomethine) phenylene · Hassan M.K., Abd-Alla M.A., Hasan R.M. · Journal of Macromolecular Science: Part A - Chemistry · 1990 · 1501-1512

6 measurement groups · 6 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Powder X-ray diffraction

Cr-BHPAP polychelate powder · Powder

Philips PW 1710 diffractometer with Ni-filtered Cu radiation.

Context
pristine coordination polymer
Measurement source
1503-1504 · Measurements; Results · text
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
XRD halo range / amorphous assignmenthalo patterns in 2theta = 5-35 deg; amorphousText
Range
1504 · Results and Discussion · text

Powder X-ray diffraction

Cu-BHPAP polychelate powder · Powder

Philips PW 1710 diffractometer with Ni-filtered Cu radiation.

Context
pristine coordination polymer
Measurement source
1503-1504 · Measurements; Results · text
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
XRD halo range / amorphous assignmenthalo patterns in 2theta = 5-35 deg; amorphousText
Range
1504 · Results and Discussion · text

Powder X-ray diffraction

Fe-BHPAP polychelate powder · Powder

Philips PW 1710 diffractometer with Ni-filtered Cu radiation.

Context
pristine coordination polymer
Measurement source
1503-1504 · Measurements; Results · text
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
XRD halo range / amorphous assignmenthalo patterns in 2theta = 5-35 deg; amorphousText
Range
1504 · Results and Discussion · text

Powder X-ray diffraction

Mn-BHPAP polychelate powder · Powder

Philips PW 1710 diffractometer with Ni-filtered Cu radiation.

Context
pristine coordination polymer
Measurement source
1503-1504 · Measurements; Results · text
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
XRD halo range / amorphous assignmenthalo patterns in 2theta = 5-35 deg; amorphousText
Range
1504 · Results and Discussion · text

Powder X-ray diffraction

Ni-BHPAP polychelate powder · Powder

Philips PW 1710 diffractometer with Ni-filtered Cu radiation.

Context
pristine coordination polymer
Measurement source
1503-1504 · Measurements; Results · text
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
XRD halo range / amorphous assignmenthalo patterns in 2theta = 5-35 deg; amorphousText
Range
1504 · Results and Discussion · text

Powder X-ray diffraction

Ti-BHPAP polychelate powder · Powder

Philips PW 1710 diffractometer with Ni-filtered Cu radiation.

Context
pristine coordination polymer
Measurement source
1503-1504 · Measurements; Results · text
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
XRD halo range / amorphous assignmenthalo patterns in 2theta = 5-35 deg; amorphousText
Range
1504 · Results and Discussion · text