time-resolved terahertz spectroscopy with Drude-Smith fitting

as-prepared SJTU-201 powder · Powder

dry N2-purged environment at room temperature; 800 nm Ti:sapphire laser; frequency-resolved photoconductivity globally fitted

Measurement source
6,92 · TRTS · Figure 5; Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
dc-limit mobility17 +/- 1 cm2 V-1 s-1+/- 1SI Table
Exact Reported
92 · Supplementary Tables · Table S4
intrinsic electron-hole sum mobilityMarked as a best value within this paper560 +/- 46 cm2 V-1 s-1+/- 46SI Table
Exact Reported
92 · Supplementary Tables · Table S4
effective mass used in TRTS fit0.154m0SI Table
Exact Reported
92 · Supplementary Tables · Table S4

time-resolved terahertz spectroscopy with Drude-Smith fitting

as-prepared SJTU-202 powder · Powder

dry N2-purged environment at room temperature; 800 nm Ti:sapphire laser; frequency-resolved photoconductivity globally fitted

Measurement source
6,92 · TRTS · Figure 5; Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
dc-limit mobility9 +/- 1 cm2 V-1 s-1+/- 1SI Table
Exact Reported
92 · Supplementary Tables · Table S4
intrinsic electron-hole sum mobility312 +/- 25 cm2 V-1 s-1+/- 25SI Table
Exact Reported
92 · Supplementary Tables · Table S4
effective mass used in TRTS fit0.276m0SI Table
Exact Reported
92 · Supplementary Tables · Table S4
global Drude-Smith backscattering parameter-0.97 +/- 0.02+/- 0.02SI Table
Exact Reported
92 · Supplementary Tables · Table S4
photoconductivity decay timeabout 2 psText
Approximate
8 · TRTS · Figure 5h
photoconductivity rise timewithin 1 psText
Approximate
8 · TRTS · Figure 5h
global Drude-Smith scattering time49 +/- 4 fs+/- 4SI Table
Exact Reported
92 · Supplementary Tables · Table S4

time-resolved terahertz spectroscopy with Drude-Smith fitting

as-prepared SJTU-203 powder · Powder

dry N2-purged environment at room temperature; 800 nm Ti:sapphire laser; frequency-resolved photoconductivity globally fitted

Measurement source
6,92 · TRTS · Figure 5; Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
dc-limit mobility13 +/- 1 cm2 V-1 s-1+/- 1SI Table
Exact Reported
92 · Supplementary Tables · Table S4
intrinsic electron-hole sum mobility418 +/- 34 cm2 V-1 s-1+/- 34SI Table
Exact Reported
92 · Supplementary Tables · Table S4
effective mass used in TRTS fit0.206m0SI Table
Exact Reported
92 · Supplementary Tables · Table S4