Elemental analysis (EA)
Im@MIL-88B-LB · Powder
C/H/N/S elemental analysis used to estimate imidazole loading per MOF formula unit.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Im@MIL-88B-LB imidazole loading | Im11.2 | — | — | SI Table Exact Reported | S14 · Results and Discussion · Table S4 |
| Solution-prepared Im@MIL-88B-LB imidazole loading | Im11.4 | — | — | SI Table Exact Reported | S4 · Preparation of Imidazole-Loaded MOFs · Table S2 |
| Im@MIL-88B-NH2 imidazole loading | Im6 | — | — | SI Table Exact Reported | S14 · Results and Discussion · Table S4 |
| Im@MIL-88B-SB imidazole loading | Im5.4 expected formula; saturated to ca. 5.5 per unit in text | — | — | SI Table Exact Reported | S14-S15 · Results and Discussion · Table S4; Figure S8 |