two-probe I-V conductivity
Cu-DDQP pellet for two-probe conductivity · Pellet
Keithley 4200-SCS source meter; voltage sweep -1.0 to 1.0 V at room temperature.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| electrical conductivity | 2.3e-06 S cm-1 | — | — | SI Table Exact Reported | S25 · Section 14 · Table S2 |
| pellet resistance | 186.92 KOhm | — | — | SI Table Exact Reported | S25 · Section 14 · Table S2 |
| pellet thickness | 0.343 mm | — | — | SI Table Exact Reported | S25 · Section 14 · Table S2 |