Other — A simplistic approach for the synthesis of Covalent Organic Frameworks(COFs) comprising of tetrafunctionalized porphyrin and polyoxometalates to uncover catalytic applications

Measurement evidence

Other

A simplistic approach for the synthesis of Covalent Organic Frameworks(COFs) comprising of tetrafunctionalized porphyrin and polyoxometalates to uncover catalytic applications · Rani S., Tariq M., Bhatti M.H. et al. · Optical Materials · 2023 · 113672

2 measurement groups · 16 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Langmuir and Freundlich adsorption isotherm analysis

P@Cu-AndCOF adsorption system on TiO2 · Unknown

100 mL P@Cu-AndCOF DMF/CH3CN solution at 2.4, 2.43, 2.47 and 2.5 mg/L; 0.03 g TiO2; stirred 2 h; UV-vis at lambda_max.

Context
P@Cu-AndCOF/TiO2 adsorption system.
Measurement source
main p.4 and p.14-15 · 2.4 Adsorption experiment; 3.8 · Figures 16-17; Tables S13-S14 referenced
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Freundlich 1/n0.52SI Table
Exact Reported
SI p.25 · Table S14 · Table S14
Freundlich KfMarked as a best value within this paper3.328971 mg/gSI Table
Exact Reported
SI p.25 · Table S14 · Table S14
Freundlich n1.90SI Table
Exact Reported
SI p.25 · Table S14 · Table S14
Freundlich R20.94SI Table
Exact Reported
SI p.25 · Table S14 · Table S14
Langmuir KL0.69 L/mgSI Table
Exact Reported
SI p.25 · Table S13 · Table S13
Langmuir qmMarked as a best value within this paper8.02 mg/gSI Table
Exact Reported
SI p.25 · Table S13 · Table S13
Langmuir correlation coefficientMarked as a best value within this paper0.95SI Table
Exact Reported
SI p.25 · Table S13 · Table S13
Langmuir RL0.23SI Table
Exact Reported
SI p.25 · Table S13 · Table S13

Langmuir and Freundlich adsorption isotherm analysis

P@Ni-AndCOF adsorption system on TiO2 · Unknown

100 mL P@Ni-AndCOF DMF/CH3CN solution at 2.4, 2.43, 2.47 and 2.5 mg/L; 0.03 g TiO2; stirred 2 h; UV-vis at lambda_max.

Context
P@Ni-AndCOF/TiO2 adsorption system.
Measurement source
main p.4 and p.14-15 · 2.4 Adsorption experiment; 3.8 · Figures 16-17; Tables S13-S14 referenced
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Freundlich 1/n0.50SI Table
Exact Reported
SI p.25 · Table S14 · Table S14
Freundlich Kf3.325676 mg/gSI Table
Exact Reported
SI p.25 · Table S14 · Table S14
Freundlich n1.99SI Table
Exact Reported
SI p.25 · Table S14 · Table S14
Freundlich R20.94SI Table
Exact Reported
SI p.25 · Table S14 · Table S14
Langmuir KL0.79 L/mgSI Table
Exact Reported
SI p.25 · Table S13 · Table S13
Langmuir qm7.44 mg/gSI Table
Exact Reported
SI p.25 · Table S13 · Table S13
Langmuir correlation coefficient0.92SI Table
Exact Reported
SI p.25 · Table S13 · Table S13
Langmuir RL0.22SI Table
Exact Reported
SI p.25 · Table S13 · Table S13