Cyclic bending test with electrical-conductivity retention
Optimised Cu3(HHTP)2/Nylon bending-test film · Thin Film
Film strips bent around a 6 mm diameter rod; conductivity ratio sigma/sigma0 tracked with bending cycles.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| bending-cycle count | 650 bending cycles | — | — | Text Exact Reported | main p.5 · 3. Results and discussion · Figure 5a |
| bending radius | 3 mm bending radius | 0.003 m | — | Text Exact Reported | main p.1,p.5 · Abstract; 3. Results and discussion · Figure 5a |
| electrical-conductivity retention after bendingMarked as a best value within this paper | about 75% of initial electrical conductivity retained after 650 bending cycles | 0.75 fraction of initial conductivity | — | Text Approximate | main p.1,p.5 · Abstract; 3. Results and discussion · Figure 5a |
| bending-test strip length | 20 mm | 0.02 m | — | Text Exact Reported | main p.5 · 3. Results and discussion · Figure 5 |
| bending-test strip width | 10 mm | 0.01 m | — | Text Exact Reported | main p.5 · 3. Results and discussion · Figure 5 |