Electrochemistry Application — Successful In Situ Growth of Conductive MOFs on 2D Cobalt-Based Compounds and Their Electrochemical Performance

Measurement evidence

Electrochemistry Application

Successful In Situ Growth of Conductive MOFs on 2D Cobalt-Based Compounds and Their Electrochemical Performance · Liu L., Zhang Y., Song Y. et al. · Inorganic Chemistry · 2024 · 10324-10334

30 measurement groups · 124 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

cyclic voltammetry (CV)

Co3O4 · Nanosheet

three-electrode cell in 3 M KOH at different sweep rates

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
substrate control
Measurement source
article p. 10329 · Results and Discussion · Figure S12a-c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CV redox behaviourCo3O4 exhibited obvious redox peaksQualitative
Qualitative
article p. 10329 · Results and Discussion · Figure S12a-c

cyclic voltammetry (CV)

Co(OH)2 · Nanosheet

three-electrode cell in 3 M KOH at different sweep rates

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
substrate control
Measurement source
article p. 10329 · Results and Discussion · Figure S12a-c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CV redox behaviourCo(OH)2 exhibited obvious redox peaksQualitative
Qualitative
article p. 10329 · Results and Discussion · Figure S12a-c

cyclic voltammetry (CV)

CoP · Nanosheet

three-electrode cell in 3 M KOH at different sweep rates

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
substrate control
Measurement source
article p. 10329 · Results and Discussion · Figure S12a-c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CV redox behaviourCoP exhibited obvious redox peaksQualitative
Qualitative
article p. 10329 · Results and Discussion · Figure S12a-c

cyclic voltammetry (CV)

Ni-HHTP@Co3O4 · Electrode

three-electrode cell in 3 M KOH; scan rates 10-50 mV s-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
target composite electrode
Measurement source
article p. 10328-10330 · Results and Discussion · Figure 5a-c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CV redox behaviourNi-HHTP@Co3O4 showed obvious redox peaks from 10-50 mV s-1Qualitative
Qualitative
article p. 10328-10330 · Results and Discussion · Figure 5a-c

cyclic voltammetry (CV)

Ni-HHTP@Co(OH)2 · Electrode

three-electrode cell in 3 M KOH; scan rates 10-50 mV s-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
target composite electrode
Measurement source
article p. 10328-10330 · Results and Discussion · Figure 5a-c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CV redox behaviourNi-HHTP@Co(OH)2 showed obvious redox peaks from 10-50 mV s-1Qualitative
Qualitative
article p. 10328-10330 · Results and Discussion · Figure 5a-c

cyclic voltammetry (CV)

Ni-HHTP@CoP · Electrode

three-electrode cell in 3 M KOH; scan rates 10-50 mV s-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
target composite electrode
Measurement source
article p. 10328-10330 · Results and Discussion · Figure 5a-c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CV redox behaviourNi-HHTP@CoP showed obvious redox peaks from 10-50 mV s-1Qualitative
Qualitative
article p. 10328-10330 · Results and Discussion · Figure 5a-c

cycling stability

Ni-HHTP@Co(OH)2//AC · Electrode

repeated GCD at 3 A g-1 for 5000 cycles

Atmosphere
aqueous 3 M KOH
Geometry
asymmetric supercapacitor
Context
device
Measurement source
article p. 10332 · Results and Discussion · Figure 6h
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
device capacitance retention after 5000 cycles at 3 A g-1Marked as a best value within this paper97.6%Text
Exact Reported
article p. 10332 · Results and Discussion · Figure 6h

cycling stability

Ni-HHTP@CoP//AC · Electrode

repeated GCD at 3 A g-1 for 5000 cycles

Atmosphere
aqueous 3 M KOH
Geometry
asymmetric supercapacitor
Context
device comparator
Measurement source
article p. 10332 · Results and Discussion · Figure S25
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
device capacitance retention after 5000 cycles at 3 A g-191.8%Text
Exact Reported
article p. 10332 · Results and Discussion · Figure S25

electrochemical impedance spectroscopy (EIS)

Ni-HHTP@Co(OH)2 · Electrode

Nyquist plots of Ni-HHTP@Co(OH)2, Ni-HHTP@CoP, and Ni-HHTP@Co3O4 fitted to transmission-line model

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
comparison among target composites
Measurement source
article p. 10331 · Results and Discussion · Figure S20
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
relative ion diffusion rateMarked as a best value within this paperNi-HHTP@Co(OH)2 shows the largest low-frequency straight-line slopeQualitative
Qualitative
article p. 10331 · Results and Discussion · Figure S20
relative charge-transfer resistanceMarked as a best value within this paperNi-HHTP@Co(OH)2 exhibits the smallest high-frequency semicircleQualitative
Qualitative
article p. 10331 · Results and Discussion · Figure S20

galvanostatic charge-discharge (GCD)

Activated carbon AC YEC-8 · Electrode

AC negative electrode in 3 M KOH, 1 A g-1 reported

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
device component
Measurement source
article p. 10331 · Results and Discussion · Figure S23
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
AC specific capacitance at 1 A g-181.25 F g-1Text
Exact Reported
article p. 10331 · Results and Discussion · Figure S23

galvanostatic charge-discharge (GCD)

Co-HHTP · Powder

three-electrode cell in 3 M KOH; Hg/HgO reference, Pt counter, nickel foam working electrode; current densities 1-5 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
pristine control
Measurement source
SI p. 16 · Electrochemical measurement · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
specific capacitance at 1 A g-1104.55 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 2 A g-199.27 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 3 A g-197.09 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 4 A g-195.27 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 5 A g-192.73 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4

galvanostatic charge-discharge (GCD)

Co-HHTP@Co3O4 · Electrode

three-electrode cell in 3 M KOH; Hg/HgO reference, Pt counter, nickel foam working electrode; current densities 1-5 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
composite electrode
Measurement source
SI p. 16 · Electrochemical measurement · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
specific capacitance at 1 A g-165.09 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 2 A g-162.55 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 3 A g-160.55 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 4 A g-159.64 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 5 A g-158.18 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4

galvanostatic charge-discharge (GCD)

Co-HHTP@Co3O4-0.5 · Electrode

three-electrode cell in 3 M KOH; Hg/HgO reference, Pt counter, nickel foam working electrode; current densities 1-5 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
composite electrode
Measurement source
SI p. 16 · Electrochemical measurement · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
specific capacitance at 1 A g-143.82 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 2 A g-141.09 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 3 A g-139.27 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 4 A g-137.82 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 5 A g-136.36 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4

galvanostatic charge-discharge (GCD)

Co-HHTP@Co(OH)2 · Electrode

three-electrode cell in 3 M KOH; Hg/HgO reference, Pt counter, nickel foam working electrode; current densities 1-5 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
composite electrode
Measurement source
SI p. 16 · Electrochemical measurement · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
specific capacitance at 1 A g-1222.91 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 2 A g-1215.64 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 3 A g-1210.55 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 4 A g-1206.55 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 5 A g-1201.83 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4

galvanostatic charge-discharge (GCD)

Co-HHTP@Co(OH)2-0.5 · Electrode

three-electrode cell in 3 M KOH; Hg/HgO reference, Pt counter, nickel foam working electrode; current densities 1-5 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
composite electrode
Measurement source
SI p. 16 · Electrochemical measurement · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
specific capacitance at 1 A g-1211.64 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 2 A g-1205.09 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 3 A g-1200.18 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 4 A g-1196.36 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 5 A g-1192.73 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4

galvanostatic charge-discharge (GCD)

Co-HHTP@CoP · Electrode

three-electrode cell in 3 M KOH; Hg/HgO reference, Pt counter, nickel foam working electrode; current densities 1-5 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
composite electrode
Measurement source
SI p. 16 · Electrochemical measurement · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
specific capacitance at 1 A g-1237.09 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 2 A g-1229.45 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 3 A g-1223.63 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 4 A g-1220.36 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 5 A g-1215.45 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4

galvanostatic charge-discharge (GCD)

Co-HHTP@CoP-0.5 · Electrode

three-electrode cell in 3 M KOH; Hg/HgO reference, Pt counter, nickel foam working electrode; current densities 1-5 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
composite electrode
Measurement source
SI p. 16 · Electrochemical measurement · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
specific capacitance at 1 A g-1169.45 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 2 A g-1162.91 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 3 A g-1155.45 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 4 A g-1149.82 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 5 A g-1128.18 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4

GCD and CV of asymmetric supercapacitor

Ni-HHTP@Co(OH)2//AC · Electrode

Ni-HHTP@Co(OH)2//AC device in 3 M KOH; 0-1.2 V CV; current densities 0.5-5.0 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
asymmetric supercapacitor
Context
device
Measurement source
article p. 10331 · Results and Discussion · Figure 6d-f
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
device specific capacitance at 0.5 A g-1Marked as a best value within this paper165 F g-1Text
Rounded Reported
article p. 10331 · Results and Discussion · Figure 6e
device specific capacitance at 1 A g-1157.83 F g-1Text
Exact Reported
article p. 10331 · Results and Discussion · Figure 6e
device specific capacitance at 2 A g-1150.5 F g-1Text
Exact Reported
article p. 10331 · Results and Discussion · Figure 6e
device specific capacitance at 3 A g-1145.75 F g-1Text
Exact Reported
article p. 10331 · Results and Discussion · Figure 6e
device specific capacitance at 4 A g-1142.33 F g-1Text
Exact Reported
article p. 10331 · Results and Discussion · Figure 6e
device specific capacitance at 5 A g-1139.17 F g-1Text
Exact Reported
article p. 10331 · Results and Discussion · Figure 6e
device energy density at 3000 W kg-127.83 Wh kg-1 at 3000 W kg-13000 W kg-1Text
Exact Reported
article p. 10331 · Results and Discussion · Figure 6g
device energy density at 600 W kg-1Marked as a best value within this paper31.57 Wh kg-1 at 600 W kg-1600 W kg-1Text
Exact Reported
article p. 10331 · Results and Discussion · Figure 6g
device capacitance retention from 0.5 to 5 A g-183.3%Text
Exact Reported
article p. 10331 · Results and Discussion · Figure 6f

galvanostatic charge-discharge (GCD)

Ni-HHTP · Powder

three-electrode cell in 3 M KOH; Hg/HgO reference, Pt counter, nickel foam working electrode; current densities 1-5 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
pristine control
Measurement source
SI p. 16 · Electrochemical measurement · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
specific capacitance at 1 A g-1143.45 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 2 A g-1115.64 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 3 A g-1100.91 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 4 A g-190.91 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 5 A g-184.55 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4

galvanostatic charge-discharge (GCD)

Ni-HHTP@Co3O4 · Electrode

three-electrode cell in 3 M KOH; Hg/HgO reference, Pt counter, nickel foam working electrode; current densities 1-5 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
composite electrode
Measurement source
SI p. 16 · Electrochemical measurement · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
specific capacitance at 1 A g-192.00 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 2 A g-180.00 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 3 A g-173.09 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 4 A g-168.36 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 5 A g-163.63 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
capacitance retention from 0.5 to 5 A g-169.17%Text
Exact Reported
article p. 10331 · Results and Discussion · Figure 5h

galvanostatic charge-discharge (GCD)

Ni-HHTP@Co3O4-0.5 · Electrode

three-electrode cell in 3 M KOH; Hg/HgO reference, Pt counter, nickel foam working electrode; current densities 1-5 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
composite electrode
Measurement source
SI p. 16 · Electrochemical measurement · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
specific capacitance at 1 A g-176.55 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 2 A g-166.90 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 3 A g-161.64 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 4 A g-158.18 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 5 A g-155.45 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4

galvanostatic charge-discharge (GCD)

Ni-HHTP@Co(OH)2 · Electrode

three-electrode cell in 3 M KOH; Hg/HgO reference, Pt counter, nickel foam working electrode; current densities 1-5 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
composite electrode
Measurement source
SI p. 16 · Electrochemical measurement · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
specific capacitance at 0.5 A g-1Marked as a best value within this paper440 F g-1Text
Rounded Reported
article p. 10329 · Results and Discussion · Figure 5d
specific capacitance at 1 A g-1Marked as a best value within this paper435.64 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 2 A g-1421.09 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 3 A g-1409.64 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 4 A g-1399.27 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 5 A g-1390.00 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
capacitance retention after 5000 cycles at 3 A g-1Marked as a best value within this paper85.4%Text
Exact Reported
article p. 10331 · Results and Discussion · Figure 5i
capacitance retention from 0.5 to 5 A g-1Marked as a best value within this paper88.64%Text
Exact Reported
article p. 10331 · Results and Discussion · Figure 5h

galvanostatic charge-discharge (GCD)

Ni-HHTP@Co(OH)2-0.5 · Electrode

three-electrode cell in 3 M KOH; Hg/HgO reference, Pt counter, nickel foam working electrode; current densities 1-5 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
composite electrode
Measurement source
SI p. 16 · Electrochemical measurement · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
specific capacitance at 1 A g-1328.72 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 2 A g-1312.72 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 3 A g-1301.09 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 4 A g-1293.09 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 5 A g-1286.36 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4

galvanostatic charge-discharge (GCD)

Ni-HHTP@CoP · Electrode

three-electrode cell in 3 M KOH; Hg/HgO reference, Pt counter, nickel foam working electrode; current densities 1-5 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
composite electrode
Measurement source
SI p. 16 · Electrochemical measurement · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
specific capacitance at 1 A g-1395.45 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 2 A g-1372.36 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 3 A g-1352.91 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 4 A g-1336.73 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 5 A g-1323.64 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
capacitance retention after 5000 cycles at 3 A g-167.3%Text
Exact Reported
article p. 10331 · Results and Discussion · Figure 5i
capacitance retention from 0.5 to 5 A g-180.54%Text
Exact Reported
article p. 10331 · Results and Discussion · Figure 5h

galvanostatic charge-discharge (GCD)

Ni-HHTP@CoP-0.5 · Electrode

three-electrode cell in 3 M KOH; Hg/HgO reference, Pt counter, nickel foam working electrode; current densities 1-5 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
composite electrode
Measurement source
SI p. 16 · Electrochemical measurement · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
specific capacitance at 1 A g-1295.45 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 2 A g-1285.45 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 3 A g-1276.55 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 4 A g-1268.36 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 5 A g-1260.00 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4

galvanostatic charge-discharge (GCD)

NiCo-HHTP · Powder

three-electrode cell in 3 M KOH; Hg/HgO reference, Pt counter, nickel foam working electrode; current densities 1-5 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
pristine control
Measurement source
SI p. 16 · Electrochemical measurement · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
specific capacitance at 1 A g-1129.46 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 2 A g-1121.46 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 3 A g-1116.18 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 4 A g-1112.00 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 5 A g-1109.09 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4

galvanostatic charge-discharge (GCD)

NiCo-HHTP@Co3O4 · Electrode

three-electrode cell in 3 M KOH; Hg/HgO reference, Pt counter, nickel foam working electrode; current densities 1-5 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
composite electrode
Measurement source
SI p. 16 · Electrochemical measurement · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
specific capacitance at 1 A g-156.36 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 2 A g-148.36 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 3 A g-143.64 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 4 A g-140.72 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 5 A g-138.18 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4

galvanostatic charge-discharge (GCD)

NiCo-HHTP@Co(OH)2 · Electrode

three-electrode cell in 3 M KOH; Hg/HgO reference, Pt counter, nickel foam working electrode; current densities 1-5 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
composite electrode
Measurement source
SI p. 16 · Electrochemical measurement · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
specific capacitance at 1 A g-1307.27 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 2 A g-1265.09 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 3 A g-1256.91 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 4 A g-1248.72 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 5 A g-1244.55 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4

galvanostatic charge-discharge (GCD)

NiCo-HHTP@CoP · Electrode

three-electrode cell in 3 M KOH; Hg/HgO reference, Pt counter, nickel foam working electrode; current densities 1-5 A g-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
composite electrode
Measurement source
SI p. 16 · Electrochemical measurement · Table S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
specific capacitance at 1 A g-1279.64 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 2 A g-1268.73 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 3 A g-1260.72 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 4 A g-1253.82 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4
specific capacitance at 5 A g-1248.18 F g-1SI Table
Exact Reported
SI p. 16 · Electrochemical measurement · Table S4

CV kinetic analysis

Ni-HHTP@Co(OH)2 · Electrode

b-value and capacitive/diffusive contribution analysis from CV curves at 10-50 mV s-1

Atmosphere
aqueous 3 M KOH
Geometry
nickel foam electrode
Context
target composite
Measurement source
article p. 10331 · Results and Discussion · Figure 6a-c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
anodic peak b value0.763Text
Exact Reported
article p. 10331 · Results and Discussion · Figure 6a
cathodic peak b value0.683Text
Exact Reported
article p. 10331 · Results and Discussion · Figure 6a
capacitive contribution at 10 mV s-1about 42.8%Figure Axis
Approximate
article p. 10330-10331 · Results and Discussion · Figure 6c
capacitive contribution at 20 mV s-1about 49.0%Figure Axis
Approximate
article p. 10330-10331 · Results and Discussion · Figure 6c
capacitive contribution at 30 mV s-1about 57.7%Figure Axis
Approximate
article p. 10330-10331 · Results and Discussion · Figure 6c
capacitive contribution at 40 mV s-1about 67.5%Figure Axis
Approximate
article p. 10330-10331 · Results and Discussion · Figure 6c
capacitive contribution at 50 mV s-1about 78.0%Text
Exact Reported
article p. 10330-10331 · Results and Discussion · Figure 6c
capacitive contribution at 50 mV s-178.0%Text
Exact Reported
article p. 10331 · Results and Discussion · Figure 6b-c