Electrochemistry Application — Bimetallic synergy significantly enhances the photocatalytic performance of lanthanide porphyrin-based MOFs: Efficient photocatalytic oxidation of benzyl alcohol and benzylamine under mild conditions in air

Measurement evidence

Electrochemistry Application

Bimetallic synergy significantly enhances the photocatalytic performance of lanthanide porphyrin-based MOFs: Efficient photocatalytic oxidation of benzyl alcohol and benzylamine under mild conditions in air · Qi Y., Cai Z., Zheng C. et al. · Journal of Catalysis · 2024 · 115226

3 measurement groups · 12 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Mott-Schottky and valence-band XPS band alignment

All reported TCPP/PMOF samples · Unknown

Mott-Schottky plots measured using electrochemical workstation with Ag/AgCl reference electrode, Pt working electrode, 0.1 M Na2SO4 electrolyte; VB from XPS.

Geometry
Ag/AgCl reference; Pt working electrode
Context
PMOF series
Measurement source
2 · Characterization procedures · Fig. S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Co-Nd PMOF conduction band position-0.80 V vs NHEText
Exact Reported
6 · 3.1 Material characterization · Fig. S4
Nd PMOF conduction band position-0.57 V vs NHEText
Exact Reported
6 · 3.1 Material characterization · Fig. S4
Ni-Nd PMOF conduction band position-1.33 V vs NHEText
Exact Reported
6 · 3.1 Material characterization · Fig. S4
Co-Nd PMOF valence band position1.32 V vs NHEText
Exact Reported
6 · 3.1 Material characterization · Fig. 5c
Nd PMOF valence band position1.61 V vs NHEText
Exact Reported
6 · 3.1 Material characterization · Fig. 5c
Ni-Nd PMOF valence band position0.65 V vs NHEText
Exact Reported
6 · 3.1 Material characterization · Fig. 5c

Electrochemical impedance spectroscopy, Nyquist plot

All reported TCPP/PMOF samples · Unknown

Electrochemical workstation, Ag/AgCl reference, Pt working electrode, 0.1 M Na2SO4 electrolyte.

Geometry
Ag/AgCl reference; Pt working electrode
Context
PMOF series
Measurement source
2 · Characterization procedures
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Co-Nd PMOF Nyquist maximum -Z double primeapproximately 3600 ohmvisual estimateFigure Axis
Approximate
6-7 · 3.1 Material characterization · Fig. 6c
Nd PMOF Nyquist maximum -Z double primeapproximately 8500 ohmvisual estimateFigure Axis
Approximate
6-7 · 3.1 Material characterization · Fig. 6c
Ni-Nd PMOF Nyquist maximum -Z double primeMarked as a best value within this paperapproximately 2500 ohmvisual estimateFigure Axis
Approximate
6-7 · 3.1 Material characterization · Fig. 6c

Transient photocurrent response

All reported TCPP/PMOF samples · Unknown

Electrochemical workstation, Ag/AgCl reference, Pt working electrode, 0.1 M Na2SO4 electrolyte, light on/off with 300 W Xe lamp.

Geometry
Ag/AgCl reference; Pt working electrode
Context
PMOF series
Measurement source
2 · Characterization procedures
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Co-Nd PMOF transient photocurrent plateauapproximately 28 mA/cm2visual estimateFigure Axis
Approximate
6 · 3.1 Material characterization · Fig. 6b
Nd PMOF transient photocurrent plateauapproximately 17 mA/cm2visual estimateFigure Axis
Approximate
6 · 3.1 Material characterization · Fig. 6b
Ni-Nd PMOF transient photocurrent plateauMarked as a best value within this paperapproximately 43 mA/cm2visual estimateFigure Axis
Approximate
6 · 3.1 Material characterization · Fig. 6b