Electrochemistry Application — Conductive Metal-Organic Framework with Superior Redox Activity as a Stable High-Capacity Anode for High-Temperature K-Ion Batteries

Measurement evidence

Electrochemistry Application

Conductive Metal-Organic Framework with Superior Redox Activity as a Stable High-Capacity Anode for High-Temperature K-Ion Batteries · Yang M., Zeng X., Xie M. et al. · Journal of the American Chemical Society · 2024 · 6753-6762

5 measurement groups · 39 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

CR2032 half-cell K-ion battery galvanostatic charge-discharge cycling

HAN-Cu-MOF KIB anode film · Electrode

0 degC; 50 mA g-1; potassium metal counter electrode; 5 M KFSI in EC:EMC 1:1

Temperature
273
Atmosphere
assembled in Ar glovebox with O2/H2O below 0.1 ppm
Geometry
CR2032 half cell
Context
HAN-Cu-MOF electrode
Measurement source
6758 · Results and Discussion · Figure S27
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
cycling capacity at 0 degC170 mAh g-1 after 100 cycles at 50 mA g-1Text
Exact Reported
6758 · Results and Discussion · Figure S27b

CR2032 half-cell K-ion battery galvanostatic charge-discharge, rate, cycling, EIS

HAN-Cu-MOF KIB anode film · Electrode

25 degC; potassium metal counter electrode; 5 M KFSI in EC:EMC 1:1

Temperature
298
Atmosphere
assembled in Ar glovebox with O2/H2O below 0.1 ppm
Geometry
CR2032 half cell
Context
HAN-Cu-MOF electrode compared with HAN control
Measurement source
6757 · Results and Discussion · Figures S21-S26
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
cycling capacity at 25 degC, 500 mA g-1Marked as a best value within this paper187 mAh g-1 after over 2000 cyclesover 2000 cyclesText
Exact Reported
6757-6758 · Results and Discussion · Figure S25; Table S2
capacity retention at 25 degC, 500 mA g-1Marked as a best value within this paperaround 100%; Table S2 >99%>SI Table
Range
S43 · Table S2 · Table S2
initial Coulombic efficiency at 25 degC44.4%Text
Exact Reported
6757 · Results and Discussion · Figure S21
initial reversible capacity at 25 degC308.7 mAh g-1 at 50 mA g-1Text
Exact Reported
6757 · Results and Discussion · Figure S21
rate capacity at 25 degC, 2000 mA g-1158.2 mAh g-1 at 2000 mA g-1Text
Exact Reported
6757 · Results and Discussion · Figure S24
HAN control capacity at 25 degC114 mAh g-1 at 50 mA g-1Text
Exact Reported
6757 · Results and Discussion · Figure S23

CR2032 half-cell K-ion battery galvanostatic charge-discharge, rate, cycling, CV

HAN-Cu-MOF KIB anode film · Electrode

45 degC; potassium metal counter electrode; 5 M KFSI in EC:EMC 1:1

Temperature
318
Atmosphere
assembled in Ar glovebox with O2/H2O below 0.1 ppm
Geometry
CR2032 half cell
Context
HAN-Cu-MOF electrode compared with HAN control
Measurement source
6757-6758 · Results and Discussion · Figure 3; Figure S30
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
cycling capacity at 45 degC, 1000 mA g-1Marked as a best value within this paper182 mAh g-1 after 1800 cyclesText
Exact Reported
6758 · Results and Discussion · Figure 3e
capacity retention at 45 degC, 1000 mA g-1Marked as a best value within this paperaround 100%aroundText
Approximate
6758 · Results and Discussion · Figure 3e
cycling capacity at 45 degC, 50 mA g-1311.7 mAh g-1 after 50 cyclesText
Exact Reported
6758 · Results and Discussion · Figure 3c
initial Coulombic efficiency at 45 degC47.4%Text
Exact Reported
6757 · Results and Discussion · Figure 3a
initial reversible capacity at 45 degC393 mAh g-1 at 50 mA g-1Text
Exact Reported
6757 · Results and Discussion · Figure 3a
rate capacity at 45 degC, 2000 mA g-1148 mAh g-1 at 2000 mA g-1Text
Exact Reported
6758 · Results and Discussion · Figure 3b
rate capacity at 45 degC, 30 mA g-1409 mAh g-1 at 30 mA g-1Text
Exact Reported
6758 · Results and Discussion · Figure 3b
CV b value cathodic peak at 45 degC0.82Text
Exact Reported
6758 · Results and Discussion · Figure S30
capacitive contribution range at 45 degC53 to 71% for scan rates 0.2 to 1.0 mV s-1rangeText
Range
6758 · Results and Discussion · Figure S30c

CR2032 half-cell K-ion battery galvanostatic charge-discharge, rate, cycling, CV, dQ/dV, EIS

HAN-Cu-MOF KIB anode film · Electrode

60 degC; potassium metal counter electrode; 5 M KFSI in EC:EMC 1:1; current densities 30-5000 mA g-1

Temperature
333
Atmosphere
assembled in Ar glovebox with O2/H2O below 0.1 ppm
Geometry
CR2032 half cell
Context
HAN-Cu-MOF electrode compared with HAN and HAN-6OH controls
Measurement source
6755-6756 · Results and Discussion · Figure 2; Figures S15-S20
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
cycling capacity at 60 degC, 1000 mA g-1Marked as a best value within this paper202.4 mAh g-1 after 1600 cyclesText
Exact Reported
6756 · Results and Discussion · Figure 2f; Table S1
capacity retention at 60 degC, 1000 mA g-1Marked as a best value within this paper96.7%Text
Exact Reported
6756 · Results and Discussion · Figure 2f; Table S1
cycling capacity at 60 degC, 500 mA g-1Marked as a best value within this paper238 mAh g-1 after 1000 cyclesText
Exact Reported
6756 · Results and Discussion · Figure 2e
capacity retention at 60 degC, 500 mA g-1Marked as a best value within this paper95.8%Text
Exact Reported
6756 · Results and Discussion · Figure 2e; Table S1
cycling capacity at 60 degC, 50 mA g-1351 mAh g-1 after 50 cyclesText
Exact Reported
6756 · Results and Discussion · Figure 2d
initial reversible specific capacity at 60 degCMarked as a best value within this paper455 mAh g-1 at 50 mA g-1Text
Exact Reported
6756 · Results and Discussion · Figure 2a
initial Coulombic efficiency at 60 degC42.7%Text
Exact Reported
6756 · Results and Discussion · Figure 2a
rate capacity at 60 degC, 2000 mA g-1Marked as a best value within this paper161 mAh g-1 at 2000 mA g-1Text
Exact Reported
6756 · Results and Discussion · Figure 2b
rate capacity at 60 degC, 30 mA g-1462 mAh g-1 at 30 mA g-1Text
Exact Reported
6756 · Results and Discussion · Figure 2b
rate capacity at 60 degC, 5000 mA g-1102 mAh g-1 at 5000 mA g-1Text
Exact Reported
6756 · Results and Discussion · Figure 2b
CV b value anodic peak at 60 degC0.94Text
Exact Reported
6758 · Results and Discussion · Figure 4a
CV b value cathodic peak at 60 degC0.91Text
Exact Reported
6758 · Results and Discussion · Figure 4a
capacitive contribution range at 60 degC58 to 76% for scan rates 0.2 to 1.0 mV s-1rangeText
Range
6758 · Results and Discussion · Figure 4b; Figure S29
first-cycle irreversible CV reduction peak0.97 VText
Exact Reported
6756 · Results and Discussion · Figure S16a
HAN control reversible capacity at 60 degC120.8 mAh g-1 at 50 mA g-1Text
Exact Reported
6756 · Results and Discussion · Figures 2a and S15
HAN-6OH control capacity121.4 mAh g-1 after 100 cycles at 1000 mA g-1Text
Exact Reported
6756 · Results and Discussion · Figure S20
HAN-6OH control capacity retention41.9% after 100 cycles at 1000 mA g-1Text
Exact Reported
6756 · Results and Discussion · Figure S20
charge transfer resistance at 60 degCMarked as a best value within this paper99 ohm for HAN-Cu-MOF; 195 ohm for HANText
Exact Reported
6756 · Results and Discussion · Figure 2c

electrode thickness, electrolyte solubility, PXRD chemical stability, post-cycling EIS/SEM

HAN-Cu-MOF KIB anode film · Electrode

Potassiation at 60 degC; electrolyte immersion in 5 M KFSI EC/EMC; solvent/acid/base exposure; post-cycling EIS after 1500 cycles

Temperature
333
Geometry
electrode film
Context
HAN-Cu-MOF electrode compared with HAN electrode
Measurement source
6758 · Results and Discussion · Figure 4; Figures S31-S32
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
electrode thickness before potassiation28.3 umText
Exact Reported
6758 · Results and Discussion · Figure 4c,d
charge transfer resistance after 1500 cycles178 ohm after 1500 cycles at 1000 mA g-1 and 60 degCText
Exact Reported
6758 · Results and Discussion · Figure 4h
charge transfer resistance before long cycling123 ohmText
Exact Reported
6758 · Results and Discussion · Figure 4h
electrolyte solubility after 30 days at 60 degCMarked as a best value within this paperno obvious dissolutionText
Qualitative
6758 · Results and Discussion · Figure 4e; Figure S31
volumetric expansion after potassiationMarked as a best value within this paperapproximately 31.4%approximatelyText
Approximate
6758 · Results and Discussion · Figure 4c,d