Other — Superhydrophilic hydrogel-enhanced conductive MOF-based wearable sweat sensors with anti-lipid biofouling capability

Measurement evidence

Other

Superhydrophilic hydrogel-enhanced conductive MOF-based wearable sweat sensors with anti-lipid biofouling capability · Liang C., Zhang H., Zhang Z. et al. · Microchemical Journal · 2025 · 114302

5 measurement groups · 18 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Hacat cell viability and live/dead staining

PDA-PAM hydrogel · Thin Film

Hacat cells treated with PDA-PAM hydrogel at 50 ug/mL for 48 h; live/dead staining with PI and FDA.

Atmosphere
cell culture
Geometry
96-well plate / cell culture assay
Context
PDA-PAM hydrogel component before/for patch integration
Measurement source
3 · 2.7 · Fig. 5b-c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Cell survival rate for PDA-PAM hydrogel patch group96.7 %Text
Exact Reported
8 · 3.4 · Fig. 5b-c

Water contact angle and underwater oil contact angle

PDA-PAM-CC hydrogel patch · Thin Film

Contact angles measured for PVA-CC, PDA-PVA-CC, PAM-CC, and PDA-PAM-CC; DCM selected as representative oil for underwater-oil contact angle.

Atmosphere
water and underwater-oil environments
Geometry
Hydrogel-coated cotton cloth patches
Context
hydrogel-CC comparison samples
Measurement source
4 · 3.2 · Fig. 3a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Water contact angle for PVA-CC, PDA-PVA-CC, PAM-CC, PDA-PAM-CC0 deg for all four hydrogel compositesText
Exact Reported
4 · 3.2 · Fig. 3a
Underwater-oil contact angle, PAM-CC142.8 degText
Exact Reported
4 · 3.2 · Fig. 3a
Underwater-oil contact angle, PDA-PAM-CCMarked as a best value within this paper152.5 degText
Exact Reported
4 · 3.2 · Fig. 3a
Underwater-oil contact angle, PDA-PVA-CC141.2 degText
Exact Reported
4 · 3.2 · Fig. 3a
Underwater-oil contact angle, PVA-CC128 degText
Exact Reported
4 · 3.2 · Fig. 3a
Oil droplet rolling angle on PDA-PAM-CCMarked as a best value within this paper4.3 degText
Exact Reported
4 · 3.2 · Fig. S2

Constant-volume dye-stained lipid diffusion test

PDA-PAM-CC hydrogel patch · Thin Film

Fixed volume dye-stained lipid dropped on gel patch; diffusion area divided by diffusion time.

Geometry
Hydrogel-coated cotton cloth patch surface
Context
hydrogel-CC comparison samples
Measurement source
6 · 3.2 · Fig. 3c-d
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Estimated lipid diffusivity, PAM-CCapproximately 0.10 cm2 s-1 from Fig. 3d axisvisual estimate, about +/-0.02Figure Axis
Approximate
6 · 3.2 · Fig. 3d
Estimated lipid diffusivity, PDA-PAM-CCMarked as a best value within this paperapproximately 0.02 cm2 s-1 from Fig. 3d axisvisual estimate, about +/-0.02Figure Axis
Approximate
6 · 3.2 · Fig. 3d
Estimated lipid diffusivity, PDA-PVA-CCapproximately 0.25 cm2 s-1 from Fig. 3d axisvisual estimate, about +/-0.03Figure Axis
Approximate
6 · 3.2 · Fig. 3d
Estimated lipid diffusivity, PVA-CCapproximately 0.40 cm2 s-1 from Fig. 3d axisvisual estimate, about +/-0.03Figure Axis
Approximate
6 · 3.2 · Fig. 3d

Tensile stress-strain and cyclic tensile testing

PDA-PAM hydrogel · Thin Film

PDA-PAM hydrogel tensile testing at 20 mm/min; cyclic tensile testing for 10 cycles at 100% strain.

Geometry
PDA-PAM hydrogel strip/sample
Context
PDA-PAM hydrogel layer before cotton-cloth integration
Measurement source
4 · 3.2 · Figs. S5-S7
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Cyclic tensile test cycles10 consecutive stretching cycles at 100% strainText
Exact Reported
4 · 3.2 · Fig. S7
PDA-PAM hydrogel elongation at break>500 %Text
Approximate
4 · 3.2 · Fig. S6
PDA-PAM hydrogel tensile strength46.5 kPaText
Exact Reported
4 · 3.2 · Fig. S6

Lipid-water separation

PDA-PAM-CC hydrogel patch · Thin Film

Sebum/water mixture poured through hydrogel-CC filter membrane under gravity; SI describes 1:5 lipid-water mixture and mass-based efficiency calculation.

Geometry
Hydrogel/CC patch fixed in customised acrylic mould for SI separation test.
Context
hydrogel-CC comparison samples
Measurement source
4 · Supporting Information · Fig. S3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Lipid-water separation efficiency, PAM-CC98.7 %Text
Exact Reported
4 · 3.2 · Fig. 3b
Lipid-water separation efficiency, PDA-PAM-CCMarked as a best value within this paper99.2 %Text
Exact Reported
4 · 3.2 · Fig. 3b
Lipid-water separation efficiency, PDA-PVA-CC95.4 %Text
Exact Reported
4 · 3.2 · Fig. 3b
Lipid-water separation efficiency, PVA-CC94.8 %Text
Exact Reported
4 · 3.2 · Fig. 3b