Two-probe electrical conductivity
c-HBC-12O-Cu pellet · Pellet
Bulk polycrystalline pellet; Keithley 4200-SCS; room-temperature conductivity; temperature-dependent measurements from 303 to 348 K also reported.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Room-temperature electrical conductivityMarked as a best value within this paper | 3.31 S m-1 | 0.0331 S cm-1 | — | SI Table Exact Reported | S23 / p023 · Electrical Conductivity · Table S3 |
| Temperature-dependent conductivity trend | Conductivity increases almost linearly with increasing temperature from 303 to 348 K | — | — | Text Qualitative | p006 / article p8984 · Results and Discussion · Figure S29 |