Computational Modelling — Millimeter-scale semiconductive metal-organic framework single crystal for X-ray imaging

Measurement evidence

Computational Modelling

Millimeter-scale semiconductive metal-organic framework single crystal for X-ray imaging · Cheng L., Liang C., Li B. et al. · Cell Reports Physical Science · 2022 · 101004

2 measurement groups · 5 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

DFT electronic-structure calculations using Dmol3 and CASTEP; PBE and PBE+U

SCU-15 DFT model sample · Model

PBE functional; DSPP for U in Dmol3; CASTEP PBE+U with U = 2.00 eV for U 5f shells, 350.0 eV cutoff, 1e-6 eV/atom SCF tolerance, 0.1 eV smearing, 5 x 3 x 5 Monkhorst-Pack grid.

Geometry
periodic unit cell
Context
SCU-15 model system
Measurement source
main p.4 and p.9 · Density functional theory calculations; Computation methods · Figure S8
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Electronic-structure mechanismLigand-to-metal charge transfer (LMCT) mechanism; conduction band edge mostly U f orbitals and valence band mostly sulfur lone-pair electrons plus benzene ringsText
Qualitative
main p.4 · Density functional theory calculations · Figure S8
DFT band-structure indirect gap shown in Figure S8indirect 1.67 eVVisual Estimate
Approximate
SI p.5 · Supplemental Items · Figure S8
PBE+U corrected band gap2.48 eVText
Exact Reported
main p.4 · Density functional theory calculations · Figure S8

X-ray attenuation efficiency calculation using XCOM mass attenuation coefficients

SCU-15 DFT model sample · Model

Calculated attenuation efficiency at 150 keV using T = 1 - exp(-mu_L x); density parameters from Table S3.

Geometry
material-thickness calculation
Context
SCU-15 material calculation
Measurement source
main p.5 and p.10 · Comparison of optoelectronic properties; X-ray attenuation efficiency calculation · Figure 4B; Figure S9; Table S3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
X-ray attenuation comparisonReduced thickness of uranium-based SCU-15 can achieve the same X-ray absorption as comparison semiconductorsText
Qualitative
main p.5 · Comparison of optoelectronic properties · Figure 4B; Figure S9
Density parameter for X-ray attenuation calculation2.120 g cm-3SI Table
Exact Reported
SI p.11 · Supplemental Items · Table S3