Microscopy Morphology — Conductive Metal-Organic Frameworks for Amperometric Sensing of Paracetamol

Measurement evidence

Microscopy Morphology

Conductive Metal-Organic Frameworks for Amperometric Sensing of Paracetamol · Wang J., Liu S., Luo J. et al. · Frontiers in Chemistry · 2020 · 594093

1 measurement group · 2 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

TEM, HAADF-STEM, HRTEM and EDX mapping

As-synthesised NiCu-CAT nanocrystals · Powder

FEI Talos F200S TEM operated at 200 kV; elemental maps for Ni, Cu, C and O.

Geometry
Nanocrystal sample on TEM grid.
Context
Pristine mixed-metal NiCu-CAT framework.
Measurement source
main p.3 · Instrumentation · Figure 2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
EDX elemental distributionNi, Cu, C and O evenly distributed throughout the nanocrystalText
Qualitative
main p.5 · Results - Characterization · Figure 2c-g; Supplementary Figure 4
NiCu-CAT nanocrystal diameter20-50 nmrangeText
Range