Differential pulse voltammetry (DPV) calibration for paracetamol
NiCu-CAT/GCE sensing electrode · Electrode
Paracetamol concentrations of 5, 10, 15, 20, 25, 30, 35, 40, 50, 70, 90, 110, 150 and 190 uM on NiCu-CAT/GCE under optimised conditions.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| DPV calibration intercept | 1.9019 uA | — | R2 = 0.9993 | Text Exact Reported | main p.7 · Analytical Performance Characteristics · Figure 5B |
| DPV calibration slopeMarked as a best value within this paper | Ipa (uA) = 0.1473 c(uM) + 1.9019; R2 = 0.9993 | — | R2 = 0.9993 | Text Exact Reported | main p.7 · Analytical Performance Characteristics · Figure 5B |
| Paracetamol DPV linear detection rangeMarked as a best value within this paper | 5-190 uM | — | range | Text Range | main p.7 · Analytical Performance Characteristics · Figure 5A-B |
| Paracetamol limit of determinationMarked as a best value within this paper | near 5 uM | — | near | Text Approximate | main p.7 · Analytical Performance Characteristics · Figure 5B |