Microscopy Morphology — Tunneling Electrical Connection to the Interior of Metal-Organic Frameworks

Measurement evidence

Microscopy Morphology

Tunneling Electrical Connection to the Interior of Metal-Organic Frameworks · Han S., Warren S.C., Yoon S.M. et al. · Journal of the American Chemical Society · 2015 · 8169-8175

1 measurement group · 1 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

TEM and HAADF-STEM/EDX

AgNC@Rb-CD-MOF from 10 mM AgNO3 · Single Crystal

TEM of AgNCs liberated after dissolving AgNC@Rb-CD-MOF; HAADF-STEM on embedded/dry-sectioned crystal

Geometry
not applicable
Context
AgNC-loaded Rb-CD-MOF
Measurement source
2 · Results and Discussion · Figure 1d; Figure S3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Apparent AgNC size after dissolution/TEMca. 2 nm; real particle size is smaller due to beam/dissolution coalescenceText
Approximate
2 · Results and Discussion · Figure 1d