3D electron diffraction tomography, HRTEM, SAED
As-synthesised Cu-DBC powder · Powder
Single submicrometre Cu-DBC crystals; specimen plus electron-beam tilt from -50 to +50 degrees with 0.3 degree beam-tilt step; HRTEM at 200 kV.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| 3D-EDT reconstructed a parameter | a = 34.8 angstrom | — | — | Text Rounded Reported | S6 · Section 6. 3D-EDT Measurement · Figure S4 |
| 3D-EDT reconstructed b parameter | b = 42.7 angstrom | — | — | Text Rounded Reported | S6 · Section 6. 3D-EDT Measurement · Figure S4 |
| 3D-EDT reconstructed c parameter | c = 14.9 angstrom | — | — | Text Rounded Reported | S6 · Section 6. 3D-EDT Measurement · Figure S4 |
| Rhombic pore spacing d020 | d020 = 21.16 angstrom | — | — | Text Exact Reported | 1082 · Results and discussion · Figure 1f,g; Figure S6 |
| Rhombic pore spacing d200 | d200 = 16.95 angstrom | — | — | Text Exact Reported | 1082 · Results and discussion · Figure 1f,g; Figure S6 |