Room-temperature four-probe conductivity and Seebeck coefficient
Ni3(THT)2 pressed pellet for four-probe and Seebeck measurements · Pellet
custom probe station in argon glovebox; forward and reverse Seebeck scans; geometry correction for conductivity and Seebeck
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Thermoelectric carrier sign | negative Seebeck; n-type thermoelectric behavior | — | — | Text Qualitative | 4 · Bulk Electronic Structure |
| Geometry-adjusted Seebeck coefficient batch 1 | -7.9 uV/K | — | — | SI Table Exact Reported | 13 · Characterization Data · Table S4 |
| Geometry-adjusted Seebeck coefficient batch 2 | -29.8 uV/K | — | — | SI Table Exact Reported | 13 · Characterization Data · Table S4 |
| Geometry-adjusted Seebeck coefficient batch 3 | -29.6 uV/K | — | — | SI Table Exact Reported | 13 · Characterization Data · Table S4 |
| Room-temperature Seebeck coefficient Fe3(THT)2 | -20.7 uV K^-1 | — | — | Text Rounded Reported | 4 · Bulk Electronic Structure |
| Room-temperature Seebeck coefficient Ni3(THT)2Marked as a best value within this paper | -22.1 uV K^-1 | — | — | Text Rounded Reported | 4 · Bulk Electronic Structure · Table S4 |
| Average bulk electrical conductivity Ni3(THT)2Marked as a best value within this paper | 0.32(9) S cm^-1 | — | (9) | Text Rounded Reported | 4 · Bulk Electronic Structure · Table S4 |
| Four-probe conductivity batch 1 | 0.18 S/cm | — | — | SI Table Exact Reported | 13 · Characterization Data · Table S4 |
| Four-probe conductivity batch 2 | 0.4 S/cm | — | — | SI Table Exact Reported | 13 · Characterization Data · Table S4 |
| Four-probe conductivity batch 3 | 0.39 S/cm | — | — | SI Table Exact Reported | 13 · Characterization Data · Table S4 |
| Bulk electrical conductivity Fe3(THT)2 comparison | 7.8(3) x 10^-2 S cm^-1 | — | (3) | Text Rounded Reported | 4 · Bulk Electronic Structure |