Diffraction Structure — Chemiresistive Sensor Arrays from Conductive 2D Metal-Organic Frameworks

Measurement evidence

Diffraction Structure

Chemiresistive Sensor Arrays from Conductive 2D Metal-Organic Frameworks · Campbell M.G., Liu S.F., Swager T.M. et al. · Journal of the American Chemical Society · 2015 · 13780-13783

2 measurement groups · 2 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Structural assignment from PXRD/literature structures

Drop-cast MOF 1-3 chemiresistor array · Electrode

Hexagonal 2D sheets stack to form extended 1D pores.

Context
pristine MOFs 1-3
Measurement source
main p002 / article page 13781 · Results · Figure S1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Extended 1D pore diameter~1.5 nmText
Approximate
main p002 / article page 13781 · Results · Figure S1

Powder X-ray diffraction (PXRD)

Drop-cast MOF 1-3 chemiresistor array · Electrode

Bruker D8 Advance with Cu K alpha source in theta/2theta Bragg-Brentano geometry; thin layer on zero-background silicon.

Context
pristine MOF powders 1-3
Measurement source
SI S2 and S6 · Instrumentation · Figure S1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
PXRD structural assignmentMOFs 1-3 adopt analogous hexagonal structuresText
Qualitative
main p002 / article page 13781 · Results · Figure S1